Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Sep 19;27(5):455-459.
doi: 10.5301/hipint.5000486. Epub 2017 Feb 18.

Excellent mid-term results of a new polished tapered modular cemented stem: a study of 113 hip replacements with minimum 5-year follow-up

Affiliations

Excellent mid-term results of a new polished tapered modular cemented stem: a study of 113 hip replacements with minimum 5-year follow-up

Jens Vanbiervliet et al. Hip Int. .

Abstract

Background: This prospective cohort study reports the medium-term clinical and radiographic results of 113 hips treated with a hybrid total hip replacement (THR) with a new cemented tapered cobalt-chrome (Co-Cr) stem with a titanium (Ti) modular neck (ProfemurXm®).

Method: Between October 2008 and December 2010 we performed 115 consecutive hybrid THR with the ProfemurXm® in 105 patients.

Results: Survivorship of the implant (stem and modular neck) at a mean of 6.5 years (min 5-max 8) was 100% with the endpoint revision for any reason. No implant was at risk for revision or showed signs of loosening. The mean Harris Hip Score was 89/100, mean Oxford Hip Score was 43/48, mean WOMAC was 91/100. No patient had thigh pain, no patient reported squeaking. There were no dislocations in this cohort. No implant showed development of radiolucent lines (RLL), either at the stem-cement or cement-bone interface. No hip showed osteolysis or calcar resorption. The mean femoral subsidence of the stem within the cement mantel was 0.31 mm (range 0-0.6 mm) after 6.5 years. With the use of this modular stem, 93% of hips showed no measurable leg length difference after THR, and leg length could be restored within a 5-mm limit in 99% of hips.

Conclusions: The mid-term results of this new polished stem were excellent, without adverse effects from the use of modularity.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: None.

References

    1. Bedard NA Callaghan JJ Stefl MD Liu SS Systematic review of literature of cemented femoral components: what is the durability at minimum 20 years followup? Clin Orthop Relat Res 2015;473(2):563–571. - PMC - PubMed
    1. Ling RS Charity J Lee AJ Whitehouse SL Timperley AJ Gie GA The long-term results of the original Exeter polished cemented femoral component: a follow-up report. J Arthroplasty 2009;24(4):511–517. - PubMed
    1. Desai AS Dramis A Board TN Leg length discrepancy after total hip arthroplasty: a review of literature. Curr Rev Musculoskelet Med 2013;6(4):336–341. - PMC - PubMed
    1. Simpson DJ Little JP Gray H Murray DW Gill HS Effect of modular neck variation on bone and cement mantle mechanics around a total hip arthroplasty stem. Clin Biomech (Bristol, Avon) 2009;24(3):274–285. - PubMed
    1. Brooker AF Bowerman JW Robinson RA Riley LH Jr Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am 1973;55(8):1629–1632. - PubMed