The uncemented, titanium-coated rm cup: Survival and analyses of failures
Abstract
This study evaluates the incidence of revision of the monoblock, uncemented, titanium-coated RM (Robert Mathys) cup (Mathys Medical, Bettlach, Switzerland) in primary total hip arthroplasty. Between 1991 and 1995 a total of 630 RM cups were implanted in 462 patients. A Kaplan-Meier survival analysis was performed with failure defined as acetabular revision for any reason. The mean follow-up was 8.2 years. A total of 34 acetabular revisions (5%) were carried out: 15 for recurrent dislocation due to cup malposition, nine for wear caused by impingement of a loose femoral component, five for aseptic loosening, only one cup was revised for articular polyethylene wear, and four for other causes. The cumulative survival rate of the RM cup is 91% at 10.7 years, with a worst case scenario of 87%. The cumulative survival rate for aseptic loosening was calculated: 99% at 10.7 years. The titanium-coated RM cup shows an impressive survival rate with revision for aseptic loosening as endpoint. Correct cup positioning is the key to success and requires experience and meticulous surgical technique. (Hip International 2005; 15: 71-7).
Similar articles
-
Mid-term clinical outcomes of the uncemented Robert Mathys pressfit cup.World J Clin Cases. 2024 Jul 6;12(19):3684-3691. doi: 10.12998/wjcc.v12.i19.3684. World J Clin Cases. 2024. PMID: 38994294 Free PMC article.
-
Does a titanium-coated polyethylene press-fit cup give reliable midterm results?Clin Orthop Relat Res. 2015 Dec;473(12):3806-10. doi: 10.1007/s11999-015-4556-7. Clin Orthop Relat Res. 2015. PMID: 26373851 Free PMC article.
-
The 45-year evolution of the Mathys RM monoblock cups: have the paradigm shifts been worthwhile?Hip Int. 2023 Mar;33(2):193-202. doi: 10.1177/11207000211067507. Epub 2022 Apr 19. Hip Int. 2023. PMID: 35438033
-
Do trabecular metal cups achieve better results when compared to hemispherical porous titanium cups in acetabular revision surgery?Hip Int. 2021 Nov;31(6):774-781. doi: 10.1177/1120700020919943. Epub 2020 May 4. Hip Int. 2021. PMID: 32363969
-
[Etiology, diagnosis and therapy of aseptic hip prosthesis loosening--a status assessment].Z Orthop Ihre Grenzgeb. 1997 Jul-Aug;135(4):270-80. doi: 10.1055/s-2008-1039388. Z Orthop Ihre Grenzgeb. 1997. PMID: 9381761 Review. German.
Cited by
-
Preliminary report of clinical experience with metal-on-highly-crosslinked-polyethylene hip resurfacing.Bone Joint Res. 2019 Nov 2;8(10):443-450. doi: 10.1302/2046-3758.810.BJR-2019-0060.R1. eCollection 2019 Oct. Bone Joint Res. 2019. PMID: 31728182 Free PMC article.
-
A cementless, elastic press-fit socket with and without screws.Acta Orthop. 2012 Oct;83(5):481-7. doi: 10.3109/17453674.2012.720116. Acta Orthop. 2012. PMID: 23083434 Free PMC article. Clinical Trial.
LinkOut - more resources
Full Text Sources