[Intramedullary placement of intraosseous cannulas inserted in the preclinical treatment of polytrauma patients : A retrospective, computed tomography-assisted evaluation]
- PMID: 28233040
- DOI: 10.1007/s00101-016-0257-1
[Intramedullary placement of intraosseous cannulas inserted in the preclinical treatment of polytrauma patients : A retrospective, computed tomography-assisted evaluation]
Abstract
Background: Use of intraosseous access to the vascular system is rare in the pre-hospital setting (<1%). However, as patients for which the use of an intraosseous device is indicated are usually in a critical condition, awareness of possible application errors is vital. A survey was performed to evaluate intramedullary needle placement by means of computed axial tomography.
Methods: In the period of 01/01/2011 to 31/12/2015 all multislice-CT trauma scans performed in a trauma center were monitored for intraosseous devices in situ. The placement site, type of intraosseous device and needle deployed, thickness of bone and soft tissues, site for optimum needle placement, and both deviation from gold standard placement and visible complications were also recorded.
Results: In 11 out of 982 patients with suspected polytrauma that were studied during the observation period, 13 intraosseous cannulas were found (1.12%). In all cases, the EZ-IO® (Teleflex, P.O. Box 12600, Research Triangle Park, NC 27709, USA) intraosseous vascular access system was used. All applications were placed correctly in the medullary cavity, but none concurred with the current guidelines: The site of the puncture deviated laterally in seven cases, medially in two cases, cranially in four cases, and caudally in two cases. The most common error in all 13 cases was overshooting during needle introduction.
Conclusion: Even though clinical criteria may suggest correct placement of an intraosseous device, the results of this survey provide evidence that deviations in positioning are common. Placement of the needle too deep can cause complications within the soft tissues or potentially impede intraosseous infusion.
Keywords: Complications; Hypovolemia; Intraosseous access; Malpositioning; Polytrauma.
Similar articles
-
Evaluation of success rate and access time for an adult sternal intraosseous device deployed in the prehospital setting.Prehosp Disaster Med. 2011 Apr;26(2):127-9. doi: 10.1017/S1049023X11000057. Prehosp Disaster Med. 2011. PMID: 21888733
-
Characteristics of Children Who Undergo Intraosseous Needle Placement.Adv Emerg Nurs J. 2015 Oct-Dec;37(4):301-7. doi: 10.1097/TME.0000000000000077. Adv Emerg Nurs J. 2015. PMID: 26509727
-
Efficacy of the EZ-IO needle driver for out-of-hospital intraosseous access--a preliminary, observational, multicenter study.Scand J Trauma Resusc Emerg Med. 2011 Oct 26;19:65. doi: 10.1186/1757-7241-19-65. Scand J Trauma Resusc Emerg Med. 2011. PMID: 22029625 Free PMC article.
-
Tibial Intraosseous Insertion in Pediatric Emergency Care: A Review Based upon Postmortem Computed Tomography.Prehosp Emerg Care. 2020 Sep-Oct;24(5):665-671. doi: 10.1080/10903127.2019.1698682. Epub 2020 Jan 7. Prehosp Emerg Care. 2020. PMID: 31774707 Review.
-
EZ-IO(®) intraosseous device implementation in a pre-hospital emergency service: A prospective study and review of the literature.Resuscitation. 2013 Apr;84(4):440-5. doi: 10.1016/j.resuscitation.2012.11.006. Epub 2012 Nov 14. Resuscitation. 2013. PMID: 23160104 Review.
Cited by
-
The relationship between intraosseous catheter tip placement, flow rates, and infusion pressures in a high bone density cadaveric swine (Sus scrofa) model.J Am Coll Emerg Physicians Open. 2024 Jul 4;5(4):e13184. doi: 10.1002/emp2.13184. eCollection 2024 Aug. J Am Coll Emerg Physicians Open. 2024. PMID: 38966284 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources