Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Feb;10(2):156-161.
doi: 10.1136/neurintsurg-2017-012991. Epub 2017 Feb 24.

Validation of cerebral arteriovenous malformation hemodynamics assessed by DSA using quantitative magnetic resonance angiography: preliminary study

Affiliations

Validation of cerebral arteriovenous malformation hemodynamics assessed by DSA using quantitative magnetic resonance angiography: preliminary study

Sophia F Shakur et al. J Neurointerv Surg. 2018 Feb.

Abstract

Background: The hemodynamic evaluation of cerebral arteriovenous malformations (AVMs) using DSA has not been validated against true flow measurements.

Objective: To validate AVM hemodynamics assessed by DSA using quantitative magnetic resonance angiography (QMRA).

Materials and methods: Patients seen at our institution between 2007 and 2016 with a supratentorial AVM and DSA and QMRA obtained before any treatment were retrospectively reviewed. DSA assessment of AVM flow comprised AVM arterial-to-venous time (A-Vt) and iFlow transit time. A-Vt was defined as the difference between peak contrast intensity in the cavernous internal carotid artery and peak contrast intensity in the draining vein. iFlow transit times were determined using syngo iFlow software. A-Vt and iFlow transit times were correlated with total AVM flow measured using QMRA and AVM angioarchitectural and clinical features.

Results: 33 patients (mean age 33 years) were included. Nine patients presented with hemorrhage. Mean AVM volume was 9.8 mL (range 0.3-57.7 mL). Both A-Vt (r=-0.47, p=0.01) and iFlow (r=-0.44, p=0.01) correlated significantly with total AVM flow. iFlow transit time was significantly shorter in patients who presented with seizure but A-Vt and iFlow did not vary with other AVM angioarchitectural features such as venous stenosis or hemorrhagic presentation.

Conclusions: A-Vt and iFlow transit times on DSA correlate with cerebral AVM flow measured using QMRA. Thus, these parameters may be used to indirectly estimate AVM flow before and after embolization during angiography in real time.

Keywords: Angiography; Arteriovenous Malformation; Blood Flow; Magnetic Resonance Angiography.

PubMed Disclaimer

Conflict of interest statement

Competing interests: AA: research grant, NIH; consultant, Cordis-Codman. FTC: ownership interest, VasSol Inc; consultant, Transonic.

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources