Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow
- PMID: 28238092
- DOI: 10.1007/s00167-017-4468-z
Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow
Abstract
Purpose: Shortening osteotomy of the proximal radius might represent a potential salvage procedure in symptomatic radiocapitellar osteoarthritis, which could decrease radiocapitellar load while preserving the native radial head. In an in-vitro biomechanical investigation, we sought to determine whether shortening osteotomy of the proximal radius (1) decreases the radiocapitellar joint pressure upon axial loading and (2) retains valgus stability of the elbow. In addition, the anatomic configuration of the lesser sigmoid notch was evaluated to assess possible contraindications.
Methods: Axial loading (0-400 N) and valgus torque (7.5 N m) over the full range of motion were applied to 14 fresh-frozen specimens before and after shortening osteotomy of the proximal radius by 2.5 mm. Radiocapitellar and ulnohumeral load distribution during axial compression was evaluated using a digital pressure mapping sensor. Valgus displacement was analyzed with a 3D camera system. The inclination angle (α) of the lesser sigmoid notch was assessed via 50 CT scans.
Results: Up to axial loading of 250 N, shortening osteotomy caused a significant decrease in radiocapitellar contact pressures (p < 0.041). Valgus stability of specimens did not differ before and after shortening osteotomy (n.s.). The mean inclination angle (α) of the lesser sigmoid notch was 11.3° ± 6.3°. 46% had an inclination angle of ≤ 10° (type I). 46% had an inclination angle of 11°-20° (type II). In 8%, the inclination angle was >20° (type III).
Conclusion: Shortening osteotomy of the proximal radius can decrease radiocapitellar contact pressures during axial loading of up to 250 N. Primary valgus stability is not relevantly influenced by this procedure. In few patients, shortening osteotomy may cause radioulnar impingement of the radial head at the distal edge of the lesser sigmoid notch due to an inclination angle of >20°. Shortening osteotomy might be a promising treatment option to decrease pain levels in case of isolated radiocapitellar osteoarthritis.
Keywords: Biomechanics; Post-traumatic osteoarthritis; Proximal radius; Radial head fracture; Salvage procedure; Shortening osteotomy.
Comment in
-
Disadvantages of having a shortening of the proximal radius.Knee Surg Sports Traumatol Arthrosc. 2017 Oct;25(10):3326-3327. doi: 10.1007/s00167-017-4599-2. Epub 2017 Jul 20. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 28730373 No abstract available.
-
Reply to the letter to the editor: shortening osteotomy of the proximal radius.Knee Surg Sports Traumatol Arthrosc. 2017 Oct;25(10):3328-3329. doi: 10.1007/s00167-017-4666-8. Epub 2017 Aug 24. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 28840264 No abstract available.
Similar articles
-
Effect of radiocapitellar Achilles disc arthroplasty on coronoid and capitellar contact pressures after radial head excision.J Shoulder Elbow Surg. 2018 Oct;27(10):1785-1791. doi: 10.1016/j.jse.2018.05.022. Epub 2018 Jul 11. J Shoulder Elbow Surg. 2018. PMID: 30007821
-
Impact of radiocapitellar interposition arthroplasty on ulnohumeral joint biomechanics.J Shoulder Elbow Surg. 2023 Mar;32(3):480-485. doi: 10.1016/j.jse.2022.09.008. Epub 2022 Oct 14. J Shoulder Elbow Surg. 2023. PMID: 36252785
-
Effects of radial head excision and distal radial shortening on load-sharing in cadaver forearms.J Bone Joint Surg Am. 2001 Jan;83(1):92-100. doi: 10.2106/00004623-200101000-00013. J Bone Joint Surg Am. 2001. PMID: 11205864
-
Radiocapitellar prosthetic arthroplasty: a report of 6 cases and review of the literature.J Shoulder Elbow Surg. 2014 Jun;23(6):843-9. doi: 10.1016/j.jse.2014.01.042. Epub 2014 Apr 13. J Shoulder Elbow Surg. 2014. PMID: 24739796 Review.
-
Optimal Prosthesis Sizing for Radial Head Arthroplasty: A Review of Current Evidence and Guidelines.JBJS Rev. 2021 Apr 22;9(4). doi: 10.2106/JBJS.RVW.20.00178. JBJS Rev. 2021. PMID: 33886524 Review.
Cited by
-
Arthroscopic matched osteoplasty of the radial head for painful radiocapitellar osteoarthritis: surgical technique and case series.Clin Shoulder Elb. 2024 Sep;27(3):309-315. doi: 10.5397/cise.2024.00073. Epub 2024 Jul 30. Clin Shoulder Elb. 2024. PMID: 39138947 Free PMC article.
-
Reply to the letter to the editor: shortening osteotomy of the proximal radius.Knee Surg Sports Traumatol Arthrosc. 2017 Oct;25(10):3328-3329. doi: 10.1007/s00167-017-4666-8. Epub 2017 Aug 24. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 28840264 No abstract available.
-
Overlengthening of the radial column in radial head replacement: a review of the literature and presentation of a classification system.Arch Orthop Trauma Surg. 2021 Sep;141(9):1525-1539. doi: 10.1007/s00402-020-03619-9. Epub 2020 Oct 14. Arch Orthop Trauma Surg. 2021. PMID: 33057805 Free PMC article. Review.
-
Radial Head Prosthesis with Interconnected Porosity Showing Low Bone Resorption Around the Stem.J Clin Med. 2025 Aug 1;14(15):5439. doi: 10.3390/jcm14155439. J Clin Med. 2025. PMID: 40807062 Free PMC article.
-
Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis.Orthop Surg. 2023 Apr;15(4):1072-1084. doi: 10.1111/os.13664. Epub 2023 Jan 16. Orthop Surg. 2023. PMID: 36647280 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous