The BiPo-3 detector

P Loaiza  1 A S Barabash  2 A Basharina-Freshville  3 E Birdsall  4 S Blondel  1 S Blot  4 M Bongrand  1 D Boursette  1 V Brudanin  5 J Busto  6 A J Caffrey  7 S Calvez  1 M Cascella  3 C Cerna  8 E Chauveau  8 A Chopra  3 S De Capua  4 D Duchesneau  9 D Durand  10 V Egorov  11 G Eurin  12 J J Evans  4 L Fajt  13 D Filosofov  11 R Flack  3 X Garrido  1 H Gómez  1 B Guillon  10 P Guzowski  4 K Holý  14 R Hodák  13 A Huber  8 C Hugon  8 A Jeremie  9 S Jullian  1 M Kauer  3 A Klimenko  11 O Kochetov  11 S I Konovalov  2 V Kovalenko  11 K Lang  15 Y Lemière  10 T Le Noblet  9 Z Liptak  15 X R Liu  3 G Lutter  8 M Macko  14 F Mamedov  13 C Marquet  8 F Mauger  10 B Morgan  16 J Mott  3 I Nemchenok  11 M Nomachi  17 F Nova  15 H Ohsumi  18 G Oliviéro  10 R B Pahlka  15 J Pater  4 F Perrot  8 F Piquemal  19 P Povinec  14 P Přidal  13 Y A Ramachers  16 A Remoto  9 B Richards  3 C L Riddle  7 E Rukhadze  13 R Saakyan  3 X Sarazin  1 Yu Shitov  20 L Simard  21 F Šimkovic  14 A Smetana  13 K Smolek  13 A Smolnikov  11 S Söldner-Rembold  4 B Soulé  8 I Štekl  13 J Thomas  3 V Timkin  11 S Torre  3 Vl I Tretyak  22 V I Tretyak  11 V I Umatov  2 C Vilela  3 V Vorobel  23 D Waters  3 A Žukauskas  23
Affiliations

The BiPo-3 detector

P Loaiza et al. Appl Radiat Isot. 2017 May.

Abstract

The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of 208Tl and 214Bi in thin materials, initially developed to measure the radiopurity of the double β decay source foils of the SuperNEMO experiment at the μBq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some μBq/kg.

Keywords: Double beta-decay detectors; Low-radioactivity measurements.