Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 May;5(3):477-485.
doi: 10.1111/andr.12334. Epub 2017 Feb 28.

Inter- and intra-laboratory standardization of TUNEL assay for assessment of sperm DNA fragmentation

Affiliations
Free article

Inter- and intra-laboratory standardization of TUNEL assay for assessment of sperm DNA fragmentation

S Ribeiro et al. Andrology. 2017 May.
Free article

Abstract

One of the challenges with the sperm DNA fragmentation results is the inconsistency and the large variability in the results obtained by different techniques. The terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay quantifies the incorporation of fluoresceinated dUTP into single- and double-strand DNA breaks by labeling the 3'-OH terminal with TdT. The goal of this study was optimize the TUNEL protocol for assessment of sperm DNA fragmentation by standardization of the method and comparison of the data across two reference laboratories (i) at Basel, Switzerland and (ii) Cleveland Clinic, Ohio, USA. Semen samples from 31 subjects grouped into three cohorts. Sperm DNA fragmentation was data measured by two experienced operators at two different laboratories using identical semen samples, assay kit, protocol and acquisition settings using identical flow cytometers (BD Accuri C6). No significant differences were observed between the duplicates in any of the experiments performed. By including an additional washing step after fixation in paraformaldehyde, a high correlation was seen between the two laboratories (r = 0.94). A strong positive correlation was observed between the average sperm DNA fragmentation rates (r = 0.719). The mean sperm DNA fragmentation measured in each laboratory was similar. Both flow cytometers were identical in their settings and performance. This inter- and intra-laboratory study establishes that TUNEL is a reproducible assay when utilizing a standardized staining protocol and flow cytometer acquisition settings. Standardization and consensual guidelines for TUNEL validate the assay and establishes TUNEL as a robust test for measuring sperm DNA fragmentation especially in a multicenter setting.

Keywords: TUNEL; DNA fragmentation; apoptosis kit; flow cytometer; spermatozoa.

PubMed Disclaimer

Publication types

LinkOut - more resources