Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr;409(11):3017-3024.
doi: 10.1007/s00216-017-0247-4. Epub 2017 Mar 1.

A simple method for forward variable selection and calibration: evaluation for compact and low-cost laser-induced breakdown spectroscopy system

Affiliations

A simple method for forward variable selection and calibration: evaluation for compact and low-cost laser-induced breakdown spectroscopy system

Fabiano Barbieri Gonzaga et al. Anal Bioanal Chem. 2017 Apr.

Abstract

This work presents a new method for forward variable selection and calibration and its evaluation for manganese determination in steel by laser-induced breakdown spectroscopy (LIBS). A compact and low-cost LIBS instrument was used, based on a microchip laser and a grating mini-spectrometer containing a non-intensified, non-gated, and non-cooled linear sensor array. Sixty steel samples were analyzed, with known manganese concentrations from 0.106 to 1.696 wt%. The spectra (1757 variables between 200 and 850 nm) were acquired under the continuous application of laser pulses at 100 Hz and using 80, 400, and 1000 ms integration times. The new method generated a mathematic combination of the selected variables and the results were calibrated against the manganese content by linear or quadratic regression. The best results were obtained using the spectra from all integration times together, with 31 selected variables and root mean square errors of cross-validation and prediction of 0.015 and 0.033, respectively. Compared to Jack-knife partial least squares regression, the new method presented lower prediction errors and numbers of selected variables, with the advantages of no data pretreatment and a simpler mathematic calculation. Graphical abstract New method for forward variable selection and calibration applied to manganese determination in steel by laser induced breakdown spectroscopy.

Keywords: Forward selection; Jack-knife; Laser-induced breakdown spectroscopy; Manganese; Partial least squares; Steel.

PubMed Disclaimer

LinkOut - more resources