Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr;33(4):463-470.
doi: 10.1016/j.cjca.2016.12.003. Epub 2016 Dec 8.

Midterm Effect of Balloon Pulmonary Angioplasty on Hemodynamics and Subclinical Myocardial Damage in Chronic Thromboembolic Pulmonary Hypertension

Affiliations

Midterm Effect of Balloon Pulmonary Angioplasty on Hemodynamics and Subclinical Myocardial Damage in Chronic Thromboembolic Pulmonary Hypertension

Mai Kimura et al. Can J Cardiol. 2017 Apr.

Abstract

Background: The acute favourable effect of balloon pulmonary angioplasty (BPA) has been proven in patients with chronic thromboembolic pulmonary hypertension (CTEPH). However, data on its effect 6 months after therapy (from now on referred to as mid-term) and influence on the right ventricle and myocardial damage are sparse. To evaluate factors that influence improvement in cardiac output (CO) and subclinical myocardial damage, we examined hemodynamics and serum high-sensitivity troponin T (hs-TnT) levels before, 1 week after, and 6 months after BPA.

Methods: In a retrospective study, we reviewed 67 consecutive patients from November 2012 to January 2016 with CTEPH who had undergone BPA at Keio University Hospital.

Results: Six months after BPA, the mean right atrium pressure, mean pulmonary artery pressure (PAP), pulmonary vascular resistance (PVR), B-type natriuretic peptide (BNP), and hs-TnT levels decreased; CO and 6-minute walking distance increased. Changes in CO and hs-TnT levels varied compared with other hemodynamic parameters and BNP levels. The CO-increase group (n = 42) had higher mean PAP and PVR, and lower CO at baseline than the CO-decrease/stable group (n = 25). The hs-TnT-decrease group (n = 36) had higher mean right atrium pressure, PAP, PVR, and BNP levels, and lower CO at baseline than the hs-TnT-increase/stable group (n = 31).

Conclusions: Six months after BPA, hemodynamics and exercise capacity improved and hs-TnT levels decreased. Improvements in CO and hs-TnT levels were more prominent in CTEPH patients with impaired baseline hemodynamics, suggesting that BPA has a favourable mid-term effect on hemodynamics and subclinical myocardial damage in patients with CTEPH, especially in those with impaired hemodynamics.