Spirometry reference values in the Brazilian population

Affiliations

Spirometry reference values in the Brazilian population

R Rufino et al. Braz J Med Biol Res. .

Abstract

The aim of the present study was to provide new spirometry reference equations in a sample of the Brazilian population for the following parameters: forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/FVC ratio, peak of expiratory flow (PEF), forced expiratory flow at 50% (FEF50%), 75% average vital capacity (FEF25-75%), and average forced expiratory flow time (FEFT). This was a prospective study using results from chest radiographs, electrocardiograms, and questionnaires to investigate the participants' respiratory symptoms, sedentarism, and comorbidities (Charlson comorbidity index). From December 2010 to July 2014, individuals were randomly selected from various locations in the state of Rio de Janeiro. All individuals were examined by a single technician in the morning at the laboratory, and performed the spirometry with the same spirometer. Spirometry values were tabulated for the creation of three equation models: linear regression, logarithmic regression, and logarithms through a method that incorporates the lambda, median, and coefficient of variation (LMS method). Initially, 7003 individuals from both genders were contacted, and 454 were recruited. The data from the new equations were compared with one Brazilian and eight international equations, resulting in a high correlation (r>0.9). The values derived from the LMS method and linear regression were very similar (P>0.5), and both could be used to acquire the reference values for Brazilian spirometry. Data derived from the equations of this study were different from the current Brazilian equation, which could be justified by the different method used.

PubMed Disclaimer

Figures

Figure 1
Figure 1. Patient recruitment flowchart. A total of 16.73% excluded or abandoned the study (12.11% during the test stage, 4.62% during spirometry); a total of 83.27% completed all phases.
Figure 2
Figure 2. Forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) in two Brazilian ethnicities. Horizontal lines indicate mean±SD.
Figure 3
Figure 3. Results of the Bland-Altman test in the forced vital capacity (FVC) in men. Rufino et al. is the present study.

Similar articles

Cited by

References

    1. Sunderman FW., Jr Current concepts of "normal values", "reference values", and "discrimination values" in clinical chemistry. Clin Chem. 1975;21:1873–1877. - PubMed
    1. SBPT Sociedade Brasileira de Pneumologia e Tisiologia. Diretrizes para Testes de Função Pulmonar. J Pneumol. 2002;28((Suppl 3)):S1–S238.
    1. Pellegrino R, Viegi G, Brusasco V, Crapo RO, Burgos F, Casaburi R, et al. Standardisation of spirometry. Eur Respir J. 2005;26:948–968. doi: 10.1183/09031936.05.00035205. - DOI - PubMed
    1. IBGE Brasília: Instituto Brasileiro de Geografia e Estatística [updated 2015 Aug 28; cited 2016 May 3] http://www.ibge.gov.br/home
    1. Pereira CAC, Sato T, Rodrigues SC. Novos valores de referência para espirometria forçada em brasileiros adultos de raça branca. J Bras Pneumol. 2007;33:397–406. doi: 10.1590/S1806-37132007000400008. - DOI - PubMed