Clinical Trial
. 2017 Oct;70(4):382-386.
doi: 10.1016/j.jjcc.2016.12.018. Epub 2017 Mar 6.

Limited fluoroscopy catheter ablation of accessory pathways in children

Affiliations
Free article
Clinical Trial

Limited fluoroscopy catheter ablation of accessory pathways in children

Moshe Swissa et al. J Cardiol. 2017 Oct.
Free article

Abstract

Background: Limited fluoroscopy ablation using 3D electro-anatomical system (3DS) has been used for arrhythmias in children, however it is not a common practice. We aimed to facilitate a fluoroscopy limited approach for ablation of accessory pathways (AP) in children.

Methods: Following electrophysiologic (EP) catheter placement a single dual-plane fluoroscopic image (right anterior oblique-30° and left anterior oblique-60° views) was acquired and the 3DS views were rotated to be a perfect match to the fluoroscopy. Ninety-four consecutive pediatric patients [mean age 11.8±4.1 (4.2-18) years, 61.7% males] with Wolf-Parkinson-White syndrome underwent ablation of an AP. Fifty-seven had manifest AP, 54 had left-sided AP (LSAP) and 40 had right-sided AP (RSAP).

Results: The acute success rate was 95.7% (90/94), with a recurrence rate of 1.1% (1/90) at a mean follow-up of 13±5.5 (4.4-22.9) months. Mean procedure and fluoroscopy times were 144±45 (55-262)min and 1.8±1.4 (0.1-5.6)min, respectively. Comparison of the first 20 procedures to the next 74 procedures demonstrated an extended procedure time (171±53min vs 135±38min, p<0.005), however the fluoroscopy time, the number of long applications, the time to effect, and the acute success rate were similar. There were no permanent ablation-related complications.

Conclusions: A limited fluoroscopy approach for ablation of AP in children using 3DS is easily acquired, adapted, reduces the fluoroscopy time, and has an excellent efficacy and safety profile.

Keywords: Accessory pathway; Catheter ablation; Electro-anatomic mapping systems; Limited fluoroscopy; Wolf–Parkinson–White syndrome.