Case Reports
. 2017 Jul:42:308-316.
doi: 10.1016/j.avsg.2016.10.043. Epub 2017 Mar 7.

The PETTICOAT Technique for Complicated Acute Stanford Type B Aortic Dissection Using a Tapered Self-Expanding Nitinol Device as Distal Uncovered Stent

Affiliations
Case Reports

The PETTICOAT Technique for Complicated Acute Stanford Type B Aortic Dissection Using a Tapered Self-Expanding Nitinol Device as Distal Uncovered Stent

Michele Antonello et al. Ann Vasc Surg. 2017 Jul.

Abstract

Background: Provisional Extension To Induce Complete Attachment (PETTICOAT) technique has shown good results in the treatment of acute type B aortic dissections (ABAD). Usually, uncovered tubular stainless steel stents are used to promote distal true lumen reattachment.

Methods: We describe the Petticoat technique using a conic self-expanding nitinol device as distal uncovered stent in five cases of complicated ABAD. We used as distal uncovered stent the single-flared E-XL (Jotec-GmbH).

Results: In one case, renal arteries were successfully stented through the large cells of the E-XL. No perioperative complications were reported. During follow-up (18-24 months), positive remodeling of the entire aorta occurred in 3 cases; in 1 case with associated thoracoabdominal aneurysm, false lumen thrombosis at the thoracic level with true lumen expansion at the visceral aorta was detected at the 18-month CT angiogram, and in 1 patient with Marfan syndrome, open surgical conversion with the E-XL explantation was performed after 24 months due to aneurysmal evolution at the visceral level.

Conclusions: The E-XL can be successfully used in ABAD. It adapts to different aortic diameters, and its major radial force promotes successful positive remodeling. The open cell structure allows visceral arteries stenting, and it can be removed without complications during open conversion.

PubMed Disclaimer

Publication types

MeSH terms