Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar 13;12(3):e0173383.
doi: 10.1371/journal.pone.0173383. eCollection 2017.

Left ventricular long axis tissue Doppler systolic velocity is independently related to heart rate and body size

Affiliations

Left ventricular long axis tissue Doppler systolic velocity is independently related to heart rate and body size

Roger E Peverill et al. PLoS One. .

Abstract

Background: The physiological factors which affect left ventricular (LV) long-axis function are not fully defined. We investigated the relationships of resting heart rate and body size with the peak velocities and amplitudes of LV systolic and early diastolic long axis motion, and also with long-axis contraction duration.

Methods: Two groups of adults free of cardiac disease underwent pulsed-wave tissue Doppler imaging at the septal and lateral mitral annular borders. Group 1 (n = 77) were healthy subjects <50 years of age and Group 2 (n = 65) were subjects between 40-80 years of age referred for stress echocardiography. Systolic excursion (SExc), duration (SDur) and peak velocity (s') and early diastolic excursion (EDExc) and peak velocity (e') were measured.

Results: SExc was not correlated with heart rate, height or body surface area (BSA) for either LV wall in either group, but SDur was inversely correlated with heart rate for both walls and both groups, and after adjustment for heart rate, males in both groups had a shorter septal SDur. Septal and lateral s` were independently and positively correlated with SExc, heart rate and height in both groups, independent of sex and age. There were no correlations of heart rate, height or BSA with either e` or EDExc for either wall in either group.

Conclusion: Heart rate and height independently modify the relationship between s` and SExc, but neither are related to EDExc or e`. These findings suggest that s` and SExc cannot be used interchangeably for the assessment of LV long-axis contraction.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

Figures

Fig 1
Fig 1. Example of the method for tracing the velocity time integrals of the systolic and early diastolic tissue Doppler signals from the mitral annulus.
Fig 2
Fig 2
Scatter plots of heart rate v septal systolic signal duration (A) and heart rate v lateral systolic signal duration (B) in Group 1.
Fig 3
Fig 3
Scatter plots of heart rate v septal s` (A) and heart rate v lateral s` (B) in Group 1.
Fig 4
Fig 4
Scatter plots of heart rate v septal SExc (A) and heart rate v lateral SExc (B) in Group 1.

Similar articles

Cited by

References

    1. Henein MY, Gibson DG (1999) Normal long axis function. Heart 81: 111–113. - PMC - PubMed
    1. Henein MY, Gibson DG (1999) Long axis function in disease. Heart 81: 229–231. - PMC - PubMed
    1. Carlsson M, Ugander M, Mosen H, Buhre T, Arheden H (2007) Atrioventricular plane displacement is the major contributor to left ventricular pumping in healthy adults, athletes, and patients with dilated cardiomyopathy. Am J Physiol Heart Circ Physiol 292: H1452–H1459. 10.1152/ajpheart.01148.2006 - DOI - PubMed
    1. Gibson DG, Francis DP (2003) Clinical assessment of left ventricular diastolic function. Heart 89: 231–238. - PMC - PubMed
    1. Simonson JS, Schiller NB (1989) Descent of the base of the left ventricle: an echocardiographic index of left ventricular function. J Am Soc Echocardiogr 2: 25–35. - PubMed

LinkOut - more resources