Evaluating the Use of Tissue Oximetry to Decrease Intensive Unit Monitoring for Free Flap Breast Reconstruction
- PMID: 28296715
- DOI: 10.1097/SAP.0000000000000999
Evaluating the Use of Tissue Oximetry to Decrease Intensive Unit Monitoring for Free Flap Breast Reconstruction
Abstract
Background: Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs.
Materials and methods: All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting.
Results: There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring.
Conclusions: The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.
Similar articles
-
Does Increased Experience with Tissue Oximetry Monitoring in Microsurgical Breast Reconstruction Lead to Decreased Flap Loss? The Learning Effect.Plast Reconstr Surg. 2016 Apr;137(4):1093-1101. doi: 10.1097/01.prs.0000481071.59025.82. Plast Reconstr Surg. 2016. PMID: 27018663
-
A Novel Free Flap Monitoring System Using Tissue Oximetry with Text Message Alerts.J Reconstr Microsurg. 2016 Jun;32(5):415-20. doi: 10.1055/s-0036-1582264. Epub 2016 May 2. J Reconstr Microsurg. 2016. PMID: 27135144
-
The effect of learning curve on flap selection, re-exploration, and salvage rates in free flaps; A retrospective analysis of 155 cases.Microsurgery. 2013 Oct;33(7):519-26. doi: 10.1002/micr.22153. Epub 2013 Aug 14. Microsurgery. 2013. PMID: 23946161
-
Impact of Continuous Two-Team Approach in Autologous Breast Reconstruction.J Reconstr Microsurg. 2017 May;33(4):298-304. doi: 10.1055/s-0037-1598199. Epub 2017 Feb 15. J Reconstr Microsurg. 2017. PMID: 28201829 Review.
-
Advances in flap monitoring and impact of enhanced recovery protocols.J Surg Oncol. 2018 Oct;118(5):758-767. doi: 10.1002/jso.25179. Epub 2018 Aug 21. J Surg Oncol. 2018. PMID: 30132901 Review.
Cited by
-
Use of Near-infrared Spectroscopy and Implantable Doppler for Postoperative Monitoring of Free Tissue Transfer for Breast Reconstruction: A Systematic Review and Meta-analysis.Plast Reconstr Surg Glob Open. 2019 Oct 29;7(10):e2437. doi: 10.1097/GOX.0000000000002437. eCollection 2019 Oct. Plast Reconstr Surg Glob Open. 2019. PMID: 31772881 Free PMC article.
-
Economic Analysis of Noninvasive Tissue Oximetry for Postoperative Monitoring of Deep Inferior Epigastric Perforator Flap Breast Reconstruction: A Review.Surg Innov. 2020 Oct;27(5):534-542. doi: 10.1177/1553350620942985. Epub 2020 Jul 23. Surg Innov. 2020. PMID: 32701027 Free PMC article. Review.
-
Hyperspectral Imaging (HSI) as a new diagnostic tool in free flap monitoring for soft tissue reconstruction: a proof of concept study.BMC Surg. 2021 Apr 30;21(1):222. doi: 10.1186/s12893-021-01232-0. BMC Surg. 2021. PMID: 33931056 Free PMC article.
-
The National Surgical Quality Improvement Program 30-Day Challenge: Microsurgical Breast Reconstruction Outcomes Reporting Reliability.Plast Reconstr Surg Glob Open. 2018 Mar 6;6(3):e1643. doi: 10.1097/GOX.0000000000001643. eCollection 2018 Mar. Plast Reconstr Surg Glob Open. 2018. PMID: 29707443 Free PMC article.
-
Near-Infrared Spectroscopy (NIRS) versus Hyperspectral Imaging (HSI) to Detect Flap Failure in Reconstructive Surgery: A Systematic Review.Life (Basel). 2022 Jan 3;12(1):65. doi: 10.3390/life12010065. Life (Basel). 2022. PMID: 35054458 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical