Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2017 Jun;208(6):W198-W207.
doi: 10.2214/AJR.16.17274. Epub 2017 Mar 16.

Comparison of Low- and Standard-Dose CT for the Diagnosis of Acute Appendicitis: A Meta-Analysis

Affiliations
Review

Comparison of Low- and Standard-Dose CT for the Diagnosis of Acute Appendicitis: A Meta-Analysis

Seong Jong Yun et al. AJR Am J Roentgenol. 2017 Jun.

Abstract

Objective: A meta-analysis was performed to compare low-dose CT and standard-dose CT in the diagnosis of acute appendicitis with an emphasis on diagnostic value.

Materials and methods: A systematic literature search for articles published through June 2016 was performed to identify studies that compared low-dose CT with standard-dose CT for the evaluation of patients suspected of having acute appendicitis. Summary estimates of sensitivity and specificity with 95% CIs were calculated using a bivariate random-effects model. Meta-regression was used to perform statistical comparisons of low-dose CT and standard-dose CT.

Results: Of 154 studies, nine studies investigating a total of 2957 patients were included in this meta-analysis. The pooled sensitivity and specificity of low-dose CT were 96.25% (95% CI, 91.88-98.31%) and 93.22% (95% CI, 88.75-96.00%), respectively. The pooled sensitivity and specificity of standard-dose CT were 96.40% (95% CI, 93.55-98.02%) and 92.17% (95% CI, 88.24-94.86%), respectively. In a joint model estimation of meta-regression, lowand standard-dose CT did not show a statistically significant difference (p = 0.71). Both lowand standard-dose CT seem to be characterized by high positive and negative predictive values across a broad spectrum of pretest probabilities for acute appendicitis.

Conclusion: Low-dose CT is highly effective for the diagnosis of suspected appendicitis and can be considered a valid alternative first-line imaging test that reduces the potential risk of exposure to ionizing radiation.

Keywords: appendicitis; low-dose CT; meta-analysis; sensitivity; specificity.

PubMed Disclaimer

LinkOut - more resources