Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2017 Mar 1;6(1):15-18.
doi: 10.1089/biores.2016.0033. eCollection 2017.

Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update

Affiliations
Review

Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update

Omar Velasco et al. Biores Open Access. .

Abstract

Our review of real-time three-dimensional echocardiography (RT3DE) discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE) in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV) function. Articles included perspective clinical studies and meta-analyses in the English language, and focused on the role of RT3DE in human subjects. Application of RT3DE includes analysis of the pericardium, right ventricular (RV) and LV cavities, wall motion, valvular disease, great vessels, congenital anomalies, and traumatic injury, such as myocardial contusion. RT3DE, through a transthoracic echocardiography (TTE), allows for increasingly accurate volume and valve motion assessment, estimated LV ejection fraction, and volume measurements. Chamber motion and LV mass approximation have been more accurately evaluated by RT3DE by improved inclusion of the third dimension and quantification of volumetric movement. Moreover, RT3DE was shown to have no statistical significance when comparing the ejection fractions of RT3DE to cardiac magnetic resonance (CMR). Analysis of RT3DE data sets of the LV endocardial exterior allows for the volume to be directly quantified for specific phases of the cardiac cycle, ranging from end systole to end diastole, eliminating error from wall motion abnormalities and asymmetrical left ventricles. RT3DE through TTE measures cardiac function with superior diagnostic accuracy in predicting LV mass, systolic function, along with LV and RV volume when compared with 2DE with comparable results to CMR.

Keywords: echocardiogram; four-dimensional; left ventricular function; left ventricular mass; left ventricular volume; real-time; right ventricular volume; stroke volume; three-dimensional; transthoracic; two-dimensional.

PubMed Disclaimer

Conflict of interest statement

No competing financial interests exist.

References

    1. Awan R, Rajpoot K. Spatial and spatio-temporal feature extraction from 4D echocardiography images. Comput Biol Med. 2015;64:138–147 - PubMed
    1. Zhang H, Abiose AK, Gupta D, et al. . Novel indices for left-ventricular dyssynchrony characterization based on highly automated segmentation from real-time 3-D echocardiography. Ultrasound Med Biol. 2013;39:72–88 - PMC - PubMed
    1. Chen R, Zhu M, Ashraf M. Non-invasive evaluation of heart function with four-dimensional echocardiography. PLoS One. 2016;11:e0154996. - PMC - PubMed
    1. Sugeng L, Weinert L, Lang RM. Left ventricular assessment using real-time three-dimensional echocardiography. Heart. 2003;89 Suppl 3:iii29–iii36 - PMC - PubMed
    1. Mehrotra R, Alagesan R, Srivastava S. Quantitative assessment of left ventricular systolic function using 3-dimensional echocardiography. Indian Heart J. 2013;65:620–628 - PMC - PubMed

LinkOut - more resources