Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 May;26(5):1500-1505.
doi: 10.1007/s00167-017-4493-y. Epub 2017 Mar 17.

Revision total knee arthroplasty with porous-coated metaphyseal sleeves provides radiographic ingrowth and stable fixation

Affiliations

Revision total knee arthroplasty with porous-coated metaphyseal sleeves provides radiographic ingrowth and stable fixation

Catherine J Fedorka et al. Knee Surg Sports Traumatol Arthrosc. 2018 May.

Abstract

Purpose: Porous-coated metaphyseal sleeves are designed to fill bone defects and facilitate osseointegration when bone loss in encountered during revision total knee arthroplasty (TKA). The purpose of this study is to evaluate short-term results of porous-coated metaphyseal sleeves with regards to implant fixation and clinical outcomes.

Methods: A retrospective review was conducted on 50 patients (79 sleeves-49 tibial and 30 femoral) who had a press-fit metaphyseal sleeve with revision TKA. Tibial and femoral bone loss was classified according to the Anderson Orthopaedic Research Institute (AORI) bone defect classification. Post-operative complications of infection, revision surgery, and dislocation were assessed. Follow-up radiographs were evaluated for signs of loosening using the criteria developed by the Knee Society. The median follow-up was 58.8 months (range 25.8-93.0 months).

Results: The bone loss classifications were 1 type 1, 30 type 2a, 2 type 2b, and 17 type 3, and with regards to the femur, 5 were type 1, 8 type 2a, 31 type 2b, and 6 type 3. At final follow-up, 41/45 (91.1%) tibial and 28/29 (96.6%) femoral sleeves showed radiographic evidence of ingrowth. Of these 69 patients, all showed radiographic evidence of bony ingrowth. Three sleeves were revised for infection and two for loosening. The re-operation rate for loosening was 5/74 (6.8%) and for any reason was 14/74 (18.9%).

Conclusions: Modular porous-coated press fit metaphyseal sleeves fill defects and provide evidence of radiographic ingrowth. Short-term stable fixation can be achieved with sleeves, which is helpful as more patients undergo revision total knee arthroplasty with greater bone loss. Longer duration studies are needed to ascertain the survival rate of these implants.

Level of evidence: IV.

Keywords: Metaphyseal defect; Porous coating; Sleeves; Total knee revision.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Knee. 2016 Jun;23 (3):545-8 - PubMed
    1. J Arthroplasty. 2015 Nov;30(11):1995-8 - PubMed
    1. Clin Orthop Relat Res. 2015 Oct;473(10 ):3176-82 - PubMed
    1. J Bone Joint Surg Am. 2016 Aug 3;98 (15):1286-91 - PubMed
    1. J Arthroplasty. 2014 Jun;29(6):1219-24 - PubMed

LinkOut - more resources