Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jun;49(6):553-559.
doi: 10.1055/s-0042-124363. Epub 2017 Mar 17.

Beyond white light: optical enhancement in conjunction with magnification colonoscopy for the assessment of mucosal healing in ulcerative colitis

Affiliations

Beyond white light: optical enhancement in conjunction with magnification colonoscopy for the assessment of mucosal healing in ulcerative colitis

Marietta Iacucci et al. Endoscopy. 2017 Jun.

Abstract

Background and study aim The I-SCAN optical enhancement (OE) system with magnification is a recently introduced combination of optical and digital electronic virtual chromoendoscopy, which enhances mucosal and vascular details. The aim of this pilot study was to investigate the use of I-SCAN OE in the assessment of inflammatory changes in ulcerative colitis (UC). Patients and methods A total of 41 consecutive patients with UC and 9 control patients were examined by I-SCAN OE (Pentax Medical, Tokyo, Japan). Targeted biopsies of the imaged areas were obtained. A new optical enhancement score focusing on mucosal and vascular changes was developed. The diagnostic accuracy of I-SCAN OE was calculated against histology using two UC histological scores - Robarts Histopathology Index (RHI) and ECAP (Extent, Chronicity, Activity, Plus additional findings). Results The overall I-SCAN OE score correlated with ECAP (r = 0.70; P < 0.001). The accuracy of the overall I-SCAN OE score to detect abnormalities by ECAP was 80 % (sensitivity 78 %, specificity 100 %). I-SCAN OE vascular and mucosal scores correlated with ECAP (r = 0.65 and 0.71, respectively; P < 0.001). The correlation between overall I-SCAN OE score and RHI was r = 0.61 (P < 0.01), and the accuracy to detect abnormalities by RHI was 68 % (sensitivity 78 %, specificity 50 %). The majority of patients with Mayo 0 had abnormalities on I-SCAN OE. Conclusion In UC, the new I-SCAN OE technology accurately identified mucosal inflammation, and correlated well with histological scores of chronic and acute changes.

PubMed Disclaimer

Conflict of interest statement

Competing interests: Dr. Iacucci has received an unrestricted research grant from Pentax USA.

Comment in

  • Video Comment on Marietta Iacucci et al.
    [No authors listed] [No authors listed] Endoscopy. 2017 Jun;49(6):v18. doi: 10.1055/s-0043-108870. Epub 2017 May 30. Endoscopy. 2017. PMID: 28561160 No abstract available.

Publication types

MeSH terms

LinkOut - more resources