Analysis of Blood Flow Characteristics in a Model of a Mature Side-to-Side Arteriovenous Fistula
- PMID: 28326557
- DOI: 10.1111/aor.12879
Analysis of Blood Flow Characteristics in a Model of a Mature Side-to-Side Arteriovenous Fistula
Abstract
The creation of an arteriovenous fistula (AVF) is a common surgical procedure in hemodialysis patients suffering from end-stage renal disease (ESRD). However, several complications may occur after surgery, including thrombosis, stenosis, and aneurysm. These complications are attributed to hemodynamics perturbations including pathophysiological wall shear stress (WSS) and flow recirculation zones. In this study, we present a computational hemodynamic analysis in a model of a mature side-to-side AVF, which is then validated by experimental measurements. Both computational and experimental results confirmed the presence of complex flow patterns within the AVF with vortices initially developing at the center of the venous region and gradually moving downstream, such that at four characteristic anastomosis lengths downstream, the flow disturbances became minimum. A complex pattern was also observed in WSS distribution with regions of low and high WSS identified in proximal vein and feeding artery, respectively. In addition, the temporal distribution of WSS varied significantly along the venous wall where a large portion of it remained above normal levels of WSS during systole while the area was largely normal during diastole. Our findings support the hypothesis that high WSS is not detrimental to immediate patency of AVF; however, other factors including low WSS and temporal and spatial gradients of WSS increase the risk of vascular access complications.
Keywords: -Computational modeling; -Experimental validation; -Flow disturbances; -Mature side-to-side model; -Wall shear stress; Arteriovenous fistula.
© 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Similar articles
-
Modified no-touch technique for radio-cephalic arteriovenous fistula increases primary patency and decreases juxta-anastomotic stenosis.J Vasc Access. 2024 May;25(3):904-913. doi: 10.1177/11297298221139339. Epub 2022 Dec 15. J Vasc Access. 2024. PMID: 36519744
-
Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application.J Vasc Access. 2016 Nov 2;17(6):512-520. doi: 10.5301/jva.5000607. Epub 2016 Oct 22. J Vasc Access. 2016. PMID: 27791257
-
In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure.J Vasc Surg. 2014 May;59(5):1410-7. doi: 10.1016/j.jvs.2013.04.055. Epub 2013 Jul 9. J Vasc Surg. 2014. PMID: 23845661
-
Surgical technique determines the outcome of the Brescia/Cimino AVF.J Vasc Access. 2017 Mar 6;18(Suppl. 1):1-4. doi: 10.5301/jva.5000698. Epub 2017 Mar 5. J Vasc Access. 2017. PMID: 28297045 Review.
-
Preoperative ultrasound still valuable for radio-cephalic arteriovenous fistula creation?J Vasc Access. 2017 Mar 6;18(Suppl. 1):5-9. doi: 10.5301/jva.5000672. Epub 2017 Mar 5. J Vasc Access. 2017. PMID: 28297059 Review.
Cited by
-
Pressure Analysis in Rigid and Flexible Real Arteriovenous Fistula with Thickness Variation In Vitro.J Funct Biomater. 2023 Jun 2;14(6):310. doi: 10.3390/jfb14060310. J Funct Biomater. 2023. PMID: 37367274 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials