Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2017 May;31(5):538-544.
doi: 10.1089/end.2016.0892. Epub 2017 Mar 22.

Urothelial Tumors and Dual-Band Imaging: A New Concept in Confocal Laser Endomicroscopy

Affiliations
Observational Study

Urothelial Tumors and Dual-Band Imaging: A New Concept in Confocal Laser Endomicroscopy

Arnaud Marien et al. J Endourol. 2017 May.

Abstract

Objectives: Confocal laser endomicroscopy (CLE) uses a low-energy laser light source to obtain microscopic histology images of bladder tissue exposed to a fluorescent dye. To evaluate the feasibility of using CLE with two fluorophores: fluorescein (FLUO) and hexylaminolevulinate (HAL) to determine histologic and cytologic bladder cancer criteria.

Methods: Patients eligible for HAL-photodynamic diagnosis-assisted transurethral resection of bladder tumor were included. The procedures were performed with the patient under regional or general anesthesia (60-90 minutes) after bladder instillation of HAL (50 mL, 8 mmol/L; Hexvix®; Ipsen, France). Resected tissue was examined ex vivo using CLE either with Cellvizio® system (CVI) single laser (488 nm) or with Cellvizio Dual system (CVII) double laser (488, 660 nm).

Results: Twenty-one patients were included, 12 examined by CVI and 9 by CVII. Sample examination on CVI after HAL-CLE-only histologic analysis was not possible because HAL is mostly cytoplasmic and gives poor details on cellular architecture. On the contrary, FLUO-CLE gives good extracellular architecture and not clear information of nucleocytoplasmic abnormality. Samples on CVII for seven out of nine patients clearly showed cytoplasm of suspect cells and nuclei. In real time, fluorescence observed on bandwidth (673-800 nm) with HAL and FLUO was associated with the presence of cancer, with a sensibility and specificity of 80% and 100%, respectively.

Conclusions: Real-time cytodetection was feasible using two fluorophores (FLUO and HAL) and the new system of CVII. This technology was useful to observe cytoplasm, nuclei, and nucleocytoplasmic abnormality, but an improved system is necessary (to overcome the overlapping of fluorescence) to increase the specificity.

Keywords: Cellvizio; confocal; dual band; microscopy; optical biopsy; urinary tract urothelial carcinoma.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources