Abstract
Objectives: This study sought to summarize the evidence on stress myocardial perfusion imaging (MPI) using cadmium-zinc-telluride (CZT) technology for the diagnosis of obstructive coronary artery disease (CAD). The CZT cameras are newly introduced, and comparative data with the conventional Anger technology (Anger-MPI) are lacking.
Background: The diagnostic accuracy of Anger-MPI for detection of angiographically significant CAD is well established; however, less evidence is available on the diagnostic accuracy of CZT-MPI.
Methods: Clinical studies comparing CZT-MPI and invasive coronary angiography were systematically searched and abstracted. Calculations of diagnostic accuracy, including sensitivity, specificity, likelihood ratios, and diagnostic odds ratio, were obtained with fixed and random effects, reporting point estimates and 95% confidence intervals.
Results: Based on our search, a total of 16 studies (N = 2,092) were included. The sensitivity of CZT-MPI was 0.84 (95% confidence interval [CI]: 0.78 to 0.89), whereas the specificity of 0.69 (95% CI: 0.62 to 0.76) was significantly reduced. The positive likelihood ratio was 2.73 (95% CI: 2.21 to 3.39), the negative likelihood ratio was 0.24 (95% CI: 0.17 to 0.31), and the diagnostic odds ratio was 11.93 (95% CI: 7.84 to 17.42). At subgroup and meta-regression analyses, the diagnostic accuracy between D-SPECT and Discovery cameras was similar (p = 0.711) and not impacted upon by smaller sample size studies (p = 0.573).
Conclusions: CZT-MPI has satisfactory sensitivity for angiographically significant CAD, but its suboptimal specificity warrants further development and research.
Keywords: cadmium-zinc-telluride; coronary artery disease; myocardial ischemia; myocardial perfusion imaging; single-photon emission computed tomography.
Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
CZT-SPECT: Reaching its Potential.JACC Cardiovasc Imaging. 2017 Jul;10(7):795-796. doi: 10.1016/j.jcmg.2017.02.003. Epub 2017 Mar 15. JACC Cardiovasc Imaging. 2017. PMID: 28330669 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous