. 2017 May-Jun;43(3):505-511.
doi: 10.1590/S1677-5538.IBJU.2015.0468.

Validation of self - confidence scale for clean urinary intermittent self - catheterization for patients and health - caregivers

Affiliations

Validation of self - confidence scale for clean urinary intermittent self - catheterization for patients and health - caregivers

Cintia Fernandes Baccarin Biaziolo et al. Int Braz J Urol. 2017 May-Jun.

Abstract

Objective: To validate a measurement instrument for clean intermittent self-catheterization for patients and health-caregivers.

Material and methods: Methodological study of instrument validation performed at a Rehabilitation Center in a University hospital for patients submitted to clean intermittent self-catheterization and their health-caregivers. Following ethical criteria, data were collected during interview with nurse staff using a Likert question form containing 16 items with 5 points each: "no confidence"=1, "little confidence"=2, "confident"=3, "very confident"=4 and "completely confident"=5. Questionnaire called "Self- Confident Scale for Clean Intermittent Self-catheterization" (SCSCISC) was constructed based on literature and previously validated (appearance and content).

Results: The instrument was validated by 122 patients and 119 health-caregivers, in a proportion of 15:1. It was observed a good linear association and sample adequacy KMO 0.931 and X2=2881.63, p<0.001. Anti-image matrix showed high values at diagonal suggesting inclusion of all factors. Screen plot analysis showed a suggestion of items maintenance in a single set. It was observed high correlation of all items with the total, alpha-Cronbach 0.944. The same results were obtained in subsamples of patients and health-caregivers.

Conclusion: The instrument showed good psychometric adequacy corroborating its use for evaluation of self-confidence during clean intermittent self-catheterization.

Keywords: Gestalt Therapy; Intermittent Urethral Catheterization; Nursing.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: None declared.

Similar articles

Cited by

References

    1. Reis RB, Zequi SC, Zeratti M., Filho . Urologia Moderna. Lemar; 2013.
    1. Guyton AG, Hall JE. Tratado de Fisiologia Médica. Elsevier; 2011.
    1. Sociedade Brasileira de Urologia . Bexiga Urinária: Cateterismo intermitente. Projeto Diretrizes. Associação Médica Brasileira e Conselho Federal de Medicina; 2008.
    1. Seth JH, Haslam C, Panicker JN. Ensuring patient adherence to clean intermittent self-catheterization. Patient Prefer Adherence. 2014;8:191–198. - PMC - PubMed
    1. Mazzo A, Souza VD, Junior, Jorge BM, Nassif A, Biaziolo CF, Cassini MF, et al. Intermittent urethral catheterization-descriptive study at a Brazilian service. Appl Nurs Res. 2014;27:170–174. - PubMed

Publication types