Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity
- PMID: 28340078
- DOI: 10.1093/europace/euw399
Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity
Abstract
Aims: During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV).
Methods and results: Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases.
Conclusion: Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Similar articles
-
Real-time integration of MDCT-derived coronary anatomy and epicardial fat: impact on epicardial electroanatomic mapping and ablation for ventricular arrhythmias.JACC Cardiovasc Imaging. 2013 Jan;6(1):42-52. doi: 10.1016/j.jcmg.2012.05.016. JACC Cardiovasc Imaging. 2013. PMID: 23328560
-
Merging three-dimensional CT with electroanatomic mapping facilitates ablation of ventricular arrhythmias originating from aortic root and great cardiac vein.J Interv Card Electrophysiol. 2021 Jan;60(1):101-108. doi: 10.1007/s10840-020-00712-2. Epub 2020 Feb 19. J Interv Card Electrophysiol. 2021. PMID: 32076921
-
Radiofrequency catheter ablation of ventricular arrhythmias originating from the continuum between the aortic sinus of Valsalva and the left ventricular summit: Electrocardiographic characteristics and correlative anatomy.Heart Rhythm. 2016 Jan;13(1):111-21. doi: 10.1016/j.hrthm.2015.08.030. Epub 2015 Aug 21. Heart Rhythm. 2016. PMID: 26304712
-
An organized approach to the localization, mapping, and ablation of outflow tract ventricular arrhythmias.J Cardiovasc Electrophysiol. 2013 Oct;24(10):1189-97. doi: 10.1111/jce.12237. Epub 2013 Sep 9. J Cardiovasc Electrophysiol. 2013. PMID: 24015911 Review.
-
Mapping and Ablation of Arrhythmias from Uncommon Sites (Aortic Cusp, Pulmonary Artery, and Left Ventricular Summit).Card Electrophysiol Clin. 2019 Dec;11(4):665-674. doi: 10.1016/j.ccep.2019.08.012. Card Electrophysiol Clin. 2019. PMID: 31706473 Review.
Cited by
-
2019 APHRS expert consensus statement on three-dimensional mapping systems for tachycardia developed in collaboration with HRS, EHRA, and LAHRS.J Arrhythm. 2020 Mar 9;36(2):215-270. doi: 10.1002/joa3.12308. eCollection 2020 Apr. J Arrhythm. 2020. PMID: 32256872 Free PMC article. Review. No abstract available.
-
Left heart function evaluation of patients with essential hypertension and paroxysmal atrial fibrillation by two-dimensional speckle tracking imaging combined with real-time three-dimensional ultrasound imaging.J Thorac Dis. 2021 Jan;13(1):322-333. doi: 10.21037/jtd-20-3577. J Thorac Dis. 2021. PMID: 33569212 Free PMC article.
-
Implementation of zero or near-zero fluoroscopy catheter ablation for idiopathic ventricular arrhythmia originating from the aortic sinus cusp.Int J Cardiovasc Imaging. 2022 Mar;38(3):497-506. doi: 10.1007/s10554-021-02432-8. Epub 2021 Oct 28. Int J Cardiovasc Imaging. 2022. PMID: 34709523 Free PMC article.
-
JCS/JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia.J Arrhythm. 2024 Jun 12;40(4):655-752. doi: 10.1002/joa3.13052. eCollection 2024 Aug. J Arrhythm. 2024. PMID: 39139890 Free PMC article. No abstract available.
-
Extra-Cavity Image Registration via the Aortic Root During Left Ventricular Mapping and Ablation.Anatol J Cardiol. 2024 Feb 8;28(4):201-7. doi: 10.14744/AnatolJCardiol.2023.3264. Online ahead of print. Anatol J Cardiol. 2024. PMID: 38327189 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical