. 2017 May;59(5):491-497.
doi: 10.1007/s00234-017-1826-y. Epub 2017 Mar 25.

Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms

Affiliations

Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms

Hye Jeong Kim et al. Neuroradiology. 2017 May.

Abstract

Purpose: Accurate and reliable measurement of aneurysm size is important for treatment planning. The purpose of this study was to determine intraobserver and interobserver variability of CTA and MRA for measurement of the size of cerebral aneurysms.

Methods: Thirty patients with 33 unruptured cerebral aneurysms (saccular, >3 mm in their maximal dimension, with no daughter sacs or lobulations) who underwent 256-row multislice CTA, 3-D TOF MRA at 3.0T, and 3D rotational angiography (3DRA) were retrospectively analyzed. Three independent observers measured the neck, height, and width of the aneurysms using the CTA and MRA images. Intraobserver and interobserver variability of CTA and MRA measurements was evaluated using the standardized difference and intraclass correlation coefficient, with 3DRA measurements as the reference standard. In addition, the mean values of the measurements using CTA and MRA were compared with those using 3DRA.

Results: The overall intraobserver and interobserver standardized differences in CTA/MRA were 12.83-15.92%/13.48-17.45% and 14.08-17.00%/12.08-17.67%, respectively. The overall intraobserver and interobserver intraclass correlation coefficients of CTA/MRA were 0.88-0.98/0.84-0.96 and 0.86-0.98/0.85-0.95, respectively. Compared to the height and width measurements, measurements of the neck dimensions showed higher intraobserver and interobserver variability. The sizes of the cerebral aneurysms measured by CTA and MRA were 1.13-9.26 and 5.20-9.67% larger than those measured by 3DRA, respectively; however, these differences were not statistically significant.

Conclusion: There were no noticeable differences between intraobserver and interobserver variability for both CTA- and MRA-based measurements of the size of cerebral aneurysms.

Keywords: CT angiography; Cerebral aneurysms; Intraobserver and interobserver variability; MR angiography; Measurement.

PubMed Disclaimer

Similar articles

Cited by

References

    1. N Engl J Med. 1998 Dec 10;339(24):1725-33 - PubMed
    1. Stroke. 2015 Aug;46(8):2368-400 - PubMed
    1. Cardiovasc Eng Technol. 2013 Mar;4(1):75-86 - PubMed
    1. AJNR Am J Neuroradiol. 2005 Nov-Dec;26(10 ):2569-72 - PubMed
    1. Radiology. 1991 Dec;181(3):721-30 - PubMed

LinkOut - more resources