Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jun;24(3):627-633.
doi: 10.1016/j.knee.2017.03.001. Epub 2017 Mar 27.

Does standing limb alignment after total knee arthroplasty predict dynamic alignment and knee loading during gait?

Affiliations

Does standing limb alignment after total knee arthroplasty predict dynamic alignment and knee loading during gait?

Charles Rivière et al. Knee. 2017 Jun.

Abstract

Background: A principle of TKA is to achieve a neutral standing coronal alignment of the limb (HKA angle) to reduce risks of implant loosening, reduce polyethylene wear, and optimize patellar tracking. Several long-term studies have questioned this because the relationship between alignment and implant survivorship is weaker than previously reported. We hypothesize that standing HKA poorly predicts implant failure because it does not predict dynamic HKA, dynamic adduction moment, and loading of the knee during gait. Therefore, the aim of our study is to assess the relationship between the standing and the dynamic (gait activity) HKAs.

Methods: A prospective study on a cohort of 35 patients treated with a posterior-stabilized TKA for primary osteoarthritis. Three months after surgery each patient had a long-leg radiograph and the limb was classified as neutrally aligned (17 patients), varus aligned (nine patients), or valgus aligned (four patients). Patients then performed a gait analysis for level walking.

Results: Standing HKA has a moderate correlation with the peak dynamic varus (r=0.318, p=0.001) and the mean and peak adduction moments (r=0.31 and r=-0.352 respectively). No significant correlation between standing HKA and the mean dynamic coronal alignment (r=0.14, p=0.449). No differences were found for dynamic frontal parameters (dynamic HKA and adduction moment) between patients defined as neutrally or varus aligned.

Conclusions: The standing HKA after TKA was of little value to predict dynamic behaviour of the limb during gait, this may explain why standing coronal alignment after TKA may have limited influence on long-term implant fixation and wear.

Keywords: Alignment; Gait analysis; HKA; TKA.

PubMed Disclaimer

LinkOut - more resources