Frequency, Predictors, and Implications of Abnormal Blood Pressure Responses During Dobutamine Stress Echocardiography
- PMID: 28351907
- PMCID: PMC5408460
- DOI: 10.1161/CIRCIMAGING.116.005444
Frequency, Predictors, and Implications of Abnormal Blood Pressure Responses During Dobutamine Stress Echocardiography
Abstract
Background: It is not known whether abnormal blood pressure (BP) responses during dobutamine stress echocardiography (DSE) are associated with abnormal test results, nor if such results indicate obstructive coronary artery disease (CAD). We sought to define the frequency of abnormal BP responses during DSE and their impact on accuracy of test results.
Methods and results: We studied 21 949 patients who underwent DSE at Mayo Clinic, Rochester, MN, grouped by peak systolic BP achieved during the test. We also analyzed a subgroup who underwent coronary angiography within 30 days after positive DSE. The positive predictive value of DSE was calculated for each BP group. Patients with hypertensive response (n=1905; 9%) were more likely to have positive DSE than those with normal (n=19 770; 90%) or hypotensive (n=274; 1%) BP responses (32% versus 21% versus 23%, respectively; P<0.0001). Angiography, performed in 1126 patients, showed obstructive CAD (≥50% stenosis) in 814 patients and severe CAD (≥70% stenosis) in 708 patients. Positive predictive value of DSE was similar for patients who had hypertensive and normal BP responses (69% versus 73%; P=0.3), considering 50% stenosis cut point. The proportion of severe CAD (≥70% stenosis) was lower in patients who had hypertensive response compared with those who had normal BP response (54% versus 65%; P=0.005).
Conclusions: Patients with hypertensive response during DSE are more likely to have stress-induced myocardial ischemia compared with those with normal or hypotensive BP responses but are not more likely to have false-positive DSE results. They are, however, less likely to have higher grade or multivessel CAD.
Keywords: blood pressure; coronary angiography; coronary artery disease; dobutamine; echocardiography.
© 2017 American Heart Association, Inc.
Figures
Comment in
-
Unraveling the Significance of Abnormal Blood Pressure Responses During Dobutamine Stress Echocardiography.Circ Cardiovasc Imaging. 2017 Apr;10(4):e006268. doi: 10.1161/CIRCIMAGING.117.006268. Circ Cardiovasc Imaging. 2017. PMID: 28351908 No abstract available.
References
-
- Sicari R, Nihoyannopoulos P, Evangelista A, Kasprzak J, Lancellotti P, Poldermans D, Voigt JU, Zamorano JL. Stress echocardiography expert consensus statement: European association of echocardiography (EAE) Eur J Echocardiogr. 2008;9:415–437. - PubMed
-
- Douglas PS, Garcia MJ, Haines DE, Lai WW, Manning WJ, Patel AR, Picard MH, Polk DM, Ragosta M, Ward RP, Weiner RB. ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 appropriate use criteria for echocardiography. J Am Coll Cardiol. 2011;57:1126–1166.
-
- Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, Budaj A, Bugiardini R, Crea F, Cuisset T, Di Mario C, Ferreira JR, Gersh BJ, Gitt AK, Hulot JS, Marx N, Opie LH, Pfisterer M, Prescott E, Ruschitzka F, Sabate M, Senior R, Taggart DP, van der Wall EE, Vrints CJ, Zamorano JL, Baumgartner H, Bax JJ, Bueno H, Dean V, Deaton C, Erol C, Fagard R, Ferrari R, Hasdai D, Hoes AW, Kirchhof P, Knuuti J, Kolh P, Lancellotti P, Linhart A, Nihoyannopoulos P, Piepoli MF, Ponikowski P, Sirnes PA, Tamargo JL, Tendera M, Torbicki A, Wijns W, Windecker S, Valgimigli M, Claeys MJ, Donner-Banzhoff N, Frank H, Funck-Brentano C, Gaemperli O, Gonzalez-Juanatey JR, Hamilos M, Husted S, James SK, Kervinen K, Kristensen SD, Maggioni AP, Pries AR, Romeo F, Ryden L, Simoons ML, Steg PG, Timmis A, Yildirir A. 2013 esc guidelines on the management of stable coronary artery disease. Eur Heart J. 2013;34:2949–3003. - PubMed
-
- Ha JW, Juracan EM, Mahoney DW, Oh JK, Shub C, Seward JB, Pellikka PA. Hypertensive response to exercise: A potential cause for new wall motion abnormality in the absence of coronary artery disease. J Am Coll Cardiol. 2002;39:323–327. - PubMed
-
- Shin JH, Shiota T, Kim YJ, Kwan J, Qin JX, Eto Y, Rodriguez LL, Thomas JD. False-positive exercise echocardiograms: Impact of sex and blood pressure response. Am Heart J. 2003;146:914–919. - PubMed