Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Feb;26(1):275-283.
doi: 10.1007/s12350-017-0855-6. Epub 2017 Mar 29.

Clinical performance of Rb-82 myocardial perfusion PET and Tc-99m-based SPECT in patients with extreme obesity

Affiliations

Clinical performance of Rb-82 myocardial perfusion PET and Tc-99m-based SPECT in patients with extreme obesity

David T Harnett et al. J Nucl Cardiol. 2019 Feb.

Abstract

Background: We evaluated the performance of stress imaging with technetium-99m-labeled tetrofosmin single-photon emission computed tomography (SPECT) and rubidium-82 positron emission tomography (PET) in patients with extreme obesity, defined as body mass index ≥40 kg/m2.

Methods: We identified patients with extreme obesity who underwent angiography in our center and either stress SPECT or PET within the previous six months. Cohorts of patients with extreme obesity and a <5% pretest likelihood of CAD who underwent SPECT (N = 25) or PET (N = 25) were also included.

Results: In total, 108 patients who underwent SPECT (N = 57) or PET (N = 51) were identified. Scan interpretation was classified as definitely normal or abnormal in 83.3% of PET and 60.5% of SPECT scans, respectively (P < .01). PET demonstrated higher diagnostic accuracy and normalcy rate. PET was found to have higher specificity for the pooled cohort. Similar findings were observed using stenosis cut-offs of ≥50% and ≥70%.

Conclusions: In patients with extreme obesity, PET enabled more definitive scan interpretation with less artifact compared to SPECT. PET provided higher diagnostic accuracy and specificity in the detection of obstructive coronary artery disease.

Keywords: Myocardial perfusion imaging; PET/CT; SPECT; obesity.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. J Nucl Cardiol. 2006 Mar-Apr;13(2):202-9 - PubMed
    1. Circulation. 2009 Jul 7;120(1):86-95 - PubMed
    1. Int J Cardiovasc Imaging. 2002 Feb;18(1):539-42 - PubMed
    1. J Am Coll Cardiol. 2011 Aug 9;58(7):740-8 - PubMed
    1. Circ Cardiovasc Imaging. 2009 Jan;2(1):16-23 - PubMed

Publication types

LinkOut - more resources