Achilles tendon stress is more sensitive to subject-specific geometry than subject-specific material properties: A finite element analysis
- PMID: 28359571
- DOI: 10.1016/j.jbiomech.2017.02.031
Achilles tendon stress is more sensitive to subject-specific geometry than subject-specific material properties: A finite element analysis
Abstract
This study used subject-specific measures of three-dimensional (3D) free Achilles tendon geometry in conjunction with a finite element method to investigate the effect of variation in subject-specific geometry and subject-specific material properties on tendon stress during submaximal isometric loading. Achilles tendons of eight participants (Aged 25-35years) were scanned with freehand 3D ultrasound at rest and during a 70% maximum voluntary isometric contraction. Ultrasound images were segmented, volume rendered and transformed into subject-specific 3D finite element meshes. The mean (±SD) lengths, volumes and cross-sectional areas of the tendons at rest were 62±13mm, 3617±984mm3 and 58±11mm2 respectively. The measured tendon strain at 70% MVIC was 5.9±1.3%. Subject-specific material properties were obtained using an optimisation approach that minimised the difference between measured and modelled longitudinal free tendon strain. Generic geometry was represented by the average mesh and generic material properties were taken from the literature. Local stresses were subsequently computed for combinations of subject-specific and generic geometry and material properties. For a given geometry, changing from generic to subject-specific material properties had little effect on the stress distribution in the tendon. In contrast, changing from generic to subject-specific geometry had a 26-fold greater effect on tendon stress distribution. Overall, these findings indicate that the stress distribution experienced by the living free Achilles tendon of a young and healthy population during voluntary loading are more sensitive to variation in tendon geometry than variation in tendon material properties.
Keywords: Achilles tendon; Finite element modelling; Material properties; Morphology; Strain; Stress; Subject specificity.
Copyright © 2017 Elsevier Ltd. All rights reserved.
Similar articles
-
Influence of altered geometry and material properties on tissue stress distribution under load in tendinopathic Achilles tendons - A subject-specific finite element analysis.J Biomech. 2019 Jan 3;82:142-148. doi: 10.1016/j.jbiomech.2018.10.027. Epub 2018 Oct 28. J Biomech. 2019. PMID: 30424837
-
Three-dimensional deformation and transverse rotation of the human free Achilles tendon in vivo during isometric plantarflexion contraction.J Appl Physiol (1985). 2014 Feb 15;116(4):376-84. doi: 10.1152/japplphysiol.01249.2013. Epub 2013 Dec 26. J Appl Physiol (1985). 2014. PMID: 24371014
-
The tendinopathic Achilles tendon does not remain iso-volumetric upon repeated loading: insights from 3D ultrasound.J Exp Biol. 2017 Sep 1;220(Pt 17):3053-3061. doi: 10.1242/jeb.159764. Epub 2017 Jun 15. J Exp Biol. 2017. PMID: 28620014
-
Subject-specific finite element analysis to characterize the influence of geometry and material properties in Achilles tendon rupture.J Biomech. 2014 Nov 28;47(15):3598-604. doi: 10.1016/j.jbiomech.2014.10.001. J Biomech. 2014. PMID: 25458149
-
In Vivo Strain Patterns in the Achilles Tendon During Dynamic Activities: A Comprehensive Survey of the Literature.Sports Med Open. 2023 Jul 19;9(1):60. doi: 10.1186/s40798-023-00604-5. Sports Med Open. 2023. PMID: 37466866 Free PMC article. Review.
Cited by
-
Combining in silico and in vitro experiments to characterize the role of fascicle twist in the Achilles tendon.Sci Rep. 2018 Sep 14;8(1):13856. doi: 10.1038/s41598-018-31587-z. Sci Rep. 2018. PMID: 30218024 Free PMC article.
-
Achilles tendon cross-sectional area at 12 weeks post-rupture relates to 1-year heel-rise height.Knee Surg Sports Traumatol Arthrosc. 2020 Jan;28(1):245-252. doi: 10.1007/s00167-019-05608-x. Epub 2019 Jul 2. Knee Surg Sports Traumatol Arthrosc. 2020. PMID: 31267192 Free PMC article.
-
Subject-Specific 3D Models to Investigate the Influence of Rehabilitation Exercises and the Twisted Structure on Achilles Tendon Strains.Front Bioeng Biotechnol. 2022 Jul 6;10:914137. doi: 10.3389/fbioe.2022.914137. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 35875495 Free PMC article.
-
Achilles Subtendon Structure and Behavior as Evidenced From Tendon Imaging and Computational Modeling.Front Sports Act Living. 2020 Jun 23;2:70. doi: 10.3389/fspor.2020.00070. eCollection 2020. Front Sports Act Living. 2020. PMID: 33345061 Free PMC article.
-
Bioinspired Technologies to Connect Musculoskeletal Mechanobiology to the Person for Training and Rehabilitation.Front Comput Neurosci. 2017 Oct 18;11:96. doi: 10.3389/fncom.2017.00096. eCollection 2017. Front Comput Neurosci. 2017. PMID: 29093676 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources