Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2017 Nov;86(5):857-865.
doi: 10.1016/j.gie.2017.03.1528. Epub 2017 Mar 30.

Narrow-band imaging versus white light versus mapping biopsy for gastric intestinal metaplasia: a prospective blinded trial

Affiliations
Comparative Study

Narrow-band imaging versus white light versus mapping biopsy for gastric intestinal metaplasia: a prospective blinded trial

James L Buxbaum et al. Gastrointest Endosc. 2017 Nov.

Abstract

Background and aims: Gastric intestinal metaplasia (GIM) is a gastric cancer precursor. Narrow-band imaging (NBI) may improve detection of GIM. We compared detection of GIM with high-definition white-light (HD-WL) endoscopy, NBI, and mapping biopsies in a population with increased gastric cancer risk.

Methods: Patients undergoing upper endoscopy had HD-WL examination by 1 endoscopist, followed by an NBI examination by a second endoscopist blinded to HD-WL findings. The location of abnormalities detected by HD-WL and NBI were recorded by a research coordinator, and targeted biopsies of abnormal areas were performed after NBI. Subsequently, 5 mapping biopsies were performed per patient. Biopsy specimens were read by a pathologist blinded to mode of acquisition. The primary outcome was the proportion of patients with GIM.

Results: We enrolled 112 patients: 107 (96%) were Hispanic or Asian, and 34 (30%) had GIM. Higher proportions of patients with GIM were detected by NBI (22/34 [65%]) and mapping (26/34 [76%]) versus HD-WL (10/34 [29%]) (P < .005 for both comparisons). GIM was detected by NBI in only 6 patients and only by mapping biopsy in 10 patients; no patient had GIM detected solely by HD-WL. Higher proportions of sites with GIM also were detected with NBI (30/57 [53%]) and mapping biopsies (38/57 [67%]) than HD-WL (16/57 [28%]) (P < .005 for both comparisons). The median number of biopsies per patient with mapping biopsies (5) was significantly higher than with NBI (2) or HD-WL (1).

Conclusions: HD-WL endoscopy is insufficient for detection of GIM in patients at increased risk for gastric cancer. NBI-targeted biopsies plus mapping biopsies should be used. (Clinical trial registration number: NCT02197351.).

PubMed Disclaimer

Publication types

MeSH terms

Associated data