Clinical usefulness of the dilute Russell viper venom time test for patients taking warfarin
- PMID: 28390037
- DOI: 10.1007/s12185-017-2228-y
Clinical usefulness of the dilute Russell viper venom time test for patients taking warfarin
Abstract
Warfarin use often causes false-positive results in the dilute Russell viper venom time test (DRVVT). Thus, three sets of guidelines-those presented by the International Society on Haemostasis and Thrombosis (ISTH), the British Committee for Standards in Haematology (BCSH), and the Clinical and Laboratory Standards Institute (CLSI)-are advocated. We evaluated the clinical usefulness of the testing methods recommended in these three guidelines using laboratory samples. Of the 242 samples from patients using warfarin, 38 were positive for lupus anticoagulant (LA). After adding normal pooled plasma (NPP) as recommended in the ISTH, BCSH, and CLSI guidelines, the number of samples testing positive for LA decreased to 13, 18, and 19, respectively. The number of samples with inconsistent results between the activated partial thromboplastin time and mixing test, and the DRVVT following the ISTH, BCSH, and CLSI guidelines were four of 205 (1.9%), 15 of 242 (6.2%), and 17 of 242 (7.0%), respectively. In patients with an international normalized ratio (INR) ≥3.0, 11 of 37 (29.7%) and 12 of 37 (32.4%) samples showed inconsistent results according to the BCSH and CLSI guidelines, respectively. The accuracy of the DRVVT result may thus decrease in markedly anticoagulated patients.
Keywords: Guideline; Lupus anticoagulants; Oral anticoagulants; Warfarin.
Similar articles
-
Recent guidelines and recommendations for laboratory detection of lupus anticoagulants.Semin Thromb Hemost. 2014 Mar;40(2):163-71. doi: 10.1055/s-0033-1364185. Epub 2014 Feb 5. Semin Thromb Hemost. 2014. PMID: 24500573
-
Commonalities and contrasts in recent guidelines for lupus anticoagulant detection.Int J Lab Hematol. 2014 Jun;36(3):364-73. doi: 10.1111/ijlh.12227. Int J Lab Hematol. 2014. PMID: 24750683 Review.
-
Laboratory diagnosis of lupus anticoagulants for patients on oral anticoagulant treatment. Performance of dilute Russell viper venom test and silica clotting time in comparison with Staclot LA.Thromb Haemost. 2002 Oct;88(4):583-6. Thromb Haemost. 2002. PMID: 12362227
-
Taipan snake venom time coupled with ecarin time enhances lupus anticoagulant detection in nonanticoagulated patients.Blood Coagul Fibrinolysis. 2016 Jun;27(4):477-80. doi: 10.1097/MBC.0000000000000486. Blood Coagul Fibrinolysis. 2016. PMID: 26656903
-
Lupus anticoagulant testing in Belgian laboratories: a comparison with the 2020 International Society on Thrombosis and Haemostasis Scientific and Standardization Committee (ISTH-SSC) guidelines.Acta Clin Belg. 2025 Jun;80(3):62-70. doi: 10.1080/17843286.2025.2519714. Epub 2025 Jun 17. Acta Clin Belg. 2025. PMID: 40525382 Review.
Cited by
-
Diagnostic analysis of lupus anticoagulant using clot waveform analysis in activated partial thromboplastin time prolonged cases: A retrospective analysis.Health Sci Rep. 2021 Mar 12;4(2):e258. doi: 10.1002/hsr2.258. eCollection 2021 Jun. Health Sci Rep. 2021. PMID: 33738342 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical