Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review
- PMID: 28390237
- PMCID: PMC5693313
- DOI: 10.1016/j.watres.2017.03.046
Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review
Abstract
Opportunistic premise (i.e., building) plumbing pathogens (OPPPs, e.g., Legionella pneumophila, Mycobacterium avium complex, Pseudomonas aeruginosa, Acanthamoeba, and Naegleria fowleri) are a significant and growing source of disease. Because OPPPs establish and grow as part of the native drinking water microbiota, they do not correspond to fecal indicators, presenting a major challenge to standard drinking water monitoring practices. Further, different OPPPs present distinct requirements for sampling, preservation, and analysis, creating an impediment to their parallel detection. The aim of this critical review is to evaluate the state of the science of monitoring OPPPs and identify a path forward for their parallel detection and quantification in a manner commensurate with the need for reliable data that is informative to risk assessment and mitigation. Water and biofilm sampling procedures, as well as factors influencing sample representativeness and detection sensitivity, are critically evaluated with respect to the five representative bacterial and amoebal OPPPs noted above. Available culturing and molecular approaches are discussed in terms of their advantages, limitations, and applicability. Knowledge gaps and research needs towards standardized approaches are identified.
Keywords: Culturing; Molecular methods; Opportunistic pathogens; Premise plumbing; Sampling procedures.
Copyright © 2017 Elsevier Ltd. All rights reserved.
Figures
References
-
- Adela Yanez M, Nocker A, Soria-Soria E, Murtula R, Martinez L, Catalan V. Quantification of viable Legionella pneumophila cells using propidium monoazide combined with quantitative PCR. Journal of Microbiological Methods. 2011;85(2):124–130. - PubMed
-
- Adrados B, Julian E, Codony F, Torrents E, Luquin M, Morato J. Prevalence and concentration of non-tuberculous mycobacteria in cooling towers by means of quantitative PCR: A prospective study. Current Microbiology. 2011;62(1):313–319. - PubMed
-
- Ahmed W, Brandes H, Gyawali P, Sidhu JPS, Toze S. Opportunistic pathogens in roof-captured rainwater samples, determined using quantitative PCR. Water Research. 2014;53:361–369. - PubMed
-
- Allegheny County Health Department. Updated guidelins for the control of Legionella in western Pennsylvania. Pittsburgh Regional Health Initiative; 2014. http://www.achd.net/infectd/pubs/pdf/2014_FINAL_Legionella_Guidelines_fo... Accesded in Dec, 2016.
-
- Allegra S, Girardot F, Grattard F, Berthelot P, Helbig JH, Pozzetto B, Riffard S. Evaluation of an immunomagnetic separation assay in combination with cultivation to improve Legionella pneumophila serogroup 1 recovery from environmental samples. Journal of Applied Microbiology. 2011;110(4):952–961. - PubMed