Unlocking the box: basic requirements for an ideal ventricular assist device controller
- PMID: 28395539
- DOI: 10.1080/17434440.2017.1318059
Unlocking the box: basic requirements for an ideal ventricular assist device controller
Abstract
A modern ventricular assist device (VAD) system comprises an implantable rotary blood pump and external components located outside the patient's body: a wearable controller connected to the pump via a percutaneous cable, wearable rechargeable batteries, battery charger, alternating- and direct-current power supplies, and a hospital device to control and monitor the system. If the blood pump is the 'heart' of a VAD system, the controller is its 'brain.' The controller drives the pump's electrical motor; varies the pump speed or flow based on user commands or feedback signals; collects, processes, and stores data; performs self-diagnostics; transmits to and receives data from other system components, i.e., hospital monitor and batteries; and provides various types of user interface - audible, visual, and tactile. Areas covered: Here we describe the essential functions and basic design of the VAD external controller and give our views on the future of this technology. Expert commentary: Controllers for VAD systems are crucial to their successful operation. The current clinically available system comprises an external power supply and patient-friendly controller unit. Future controller solutions may enable remote hospital monitoring, more intuitive system interface, and the potential to use a single controller to automatically control a biventricular assist device configuration.
Keywords: Electronic controller; Pumps, heart-assist; electric power supplies; heart failure; mechanical circulatory system; ventricular assist devices.
Similar articles
-
Implantable physiologic controller for left ventricular assist devices with telemetry capability.J Thorac Cardiovasc Surg. 2014 Jan;147(1):192-202. doi: 10.1016/j.jtcvs.2013.09.012. Epub 2013 Oct 29. J Thorac Cardiovasc Surg. 2014. PMID: 24176267
-
In Vivo Evaluation of Active and Passive Physiological Control Systems for Rotary Left and Right Ventricular Assist Devices.Artif Organs. 2016 Sep;40(9):894-903. doi: 10.1111/aor.12654. Epub 2016 Jan 8. Artif Organs. 2016. PMID: 26748566
-
Re-imagining the future state of the ventricular assist device controller interface through human-centered design.Artif Organs. 2024 Nov;48(11):1313-1345. doi: 10.1111/aor.14817. Epub 2024 Jul 17. Artif Organs. 2024. PMID: 39016684
-
Rotary piston blood pumps: past developments and future potential of a unique pump type.Expert Rev Med Devices. 2016 Aug;13(8):759-71. doi: 10.1080/17434440.2016.1207522. Epub 2016 Jul 11. Expert Rev Med Devices. 2016. PMID: 27353827 Review.
-
Human Factors and User Experience Issues with Ventricular Assist Device Wearable Components: A Systematic Review.Ann Biomed Eng. 2019 Dec;47(12):2431-2488. doi: 10.1007/s10439-019-02303-3. Epub 2019 Jul 23. Ann Biomed Eng. 2019. PMID: 31342334
Cited by
-
Universal ventricular assist device for right and left circulatory support: the Cleveland Clinic concept.Ann Cardiothorac Surg. 2021 Mar;10(2):271-273. doi: 10.21037/acs-2020-cfmcs-22. Ann Cardiothorac Surg. 2021. PMID: 33842222 Free PMC article. No abstract available.
-
Biventricular circulatory support using single-device and dual-device configurations: Initial pump characterization in simulated heart failure model.Front Cardiovasc Med. 2023 Feb 22;10:1045656. doi: 10.3389/fcvm.2023.1045656. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 36910535 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources