. 2017 Jan-Mar;42(1):48-54.
doi: 10.4103/0971-6203.202425.

Assessment of Regional Pediatric Computed Tomography Dose Indices in Tamil Nadu

Affiliations

Assessment of Regional Pediatric Computed Tomography Dose Indices in Tamil Nadu

A Saravanakumar et al. J Med Phys. 2017 Jan-Mar.

Abstract

The aim of this article is to assess Tamil Nadu pediatric computed tomography (CT) diagnostic reference levels (DRLs) by collecting radiation dose data for the most commonly performed CT examinations. This work was performed for thirty CT scanners installed in various parts of the Tamil Nadu region. The patient cohort was divided into two age groups: <1 year, and 1-5 years. CT dose indices were measured using a 10 cm3 pencil ion chamber with pediatric head and body polymethyl methacrylate phantoms. Dose data such as volumetric CT dose index (CTDIv) and dose length product (DLP) on a minimum of twenty average-sized pediatric patients in each category were recorded to calculate a mean site CTDIv and DLP value. The rounded 75th percentile was used to calculate a pediatric DRL for each hospital, and then region by compiling all results. Data were collected for 3600 pediatric patients. Pediatric CT DRL for two age groups: <1 year (CTDIv and DLP of head [20 mGy, 352 mGy.cm], chest [7 mGy, 120 mGy.cm] and abdomen [12 mGy, 252 mGy.cm]), and 1-5 years (CTDIv and DLP of head [38 mGy, 505 mGy.cm], chest [8 mGy, 132 mGy.cm] and abdomen [14 mGy, 270 mGy.cm]) for select procedures have been calculated. Proposed pediatric DRLs of CTDIv and DLP for head procedure were lower, and for chest and abdomen procedures were higher than European pediatric DRLs for both age groups.

Keywords: Diagnostic reference level; pediatric computed tomography; pediatric computed tomography diagnostic reference level; volumetric computed tomography dose index.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

Figures

Figure 1
Figure 1
Calculated volumetric computed tomography dose index for <1 year and 1–5 years age group of pediatric patients for select procedures.
Figure 2
Figure 2
Calculated dose length product for <1 year and 1–5 years age group of pediatric patients for select procedures.

References

    1. Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG, et al. Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large Children's Hospital. AJR Am J Roentgenol. 2001;176:303–6. - PubMed
    1. Lam W, Wendy WM Lam. Pediatric CT radiation risks: What you should know. Med Bull. 2006;11:5–7.
    1. Brenner David J. One size does not fit all: Reducing risks from pediatric CT. ACR Bull. 2001;57:20–3.
    1. Frush DP, Donnelly LF, Rosen NS. Computed tomography and radiation risks: What pediatric health care providers should know. Pediatrics. 2003;112:951–7. - PubMed