Elliptical broken line method for calculating capillary density in nailfold capillaroscopy: Proposal and evaluation
- PMID: 28414021
- DOI: 10.1016/j.mvr.2017.04.002
Elliptical broken line method for calculating capillary density in nailfold capillaroscopy: Proposal and evaluation
Abstract
Nailfold capillaroscopy is a practical method for identifying and obtaining morphological changes in capillaries which might reveal relevant information about diseases and health. Capillaroscopy is harmless, and seems simple and repeatable. However, there is lack of established guidelines and instructions for acquisition as well as the interpretation of the obtained images; which might lead to various ambiguities. In addition, assessment and interpretation of the acquired images are very subjective. In an attempt to overcome some of these problems, in this study a new modified technique for assessment of nailfold capillary density is introduced. The new method is named elliptic broken line (EBL) which is an extension of the two previously known methods by defining clear criteria for finding the apex of capillaries in different scenarios by using a fitted elliptic. A graphical user interface (GUI) is developed for pre-processing, manual assessment of capillary apexes and automatic correction of selected apexes based on 90° rule. Intra- and inter-observer reliability of EBL and corrected EBL is evaluated in this study. Four independent observers familiar with capillaroscopy performed the assessment for 200 nailfold videocapillaroscopy images, form healthy subject and systemic lupus erythematosus patients, in two different sessions. The results show elevation from moderate (ICC=0.691) and good (ICC=0.753) agreements to good (ICC=0.750) and good (ICC=0.801) for intra- and inter-observer reliability after automatic correction of EBL. This clearly shows the potential of this method to improve the reliability and repeatability of assessment which motivates us for further development of automatic tool for EBL method.
Keywords: Capillary density; Nailfold capillaroscopy; Number of papillae; Reliability; Repeatability.
Copyright © 2017 Elsevier Inc. All rights reserved.
Similar articles
-
Practical issues in assessing nailfold capillaroscopic images: a summary.Clin Rheumatol. 2019 Sep;38(9):2343-2354. doi: 10.1007/s10067-019-04644-9. Epub 2019 Jul 5. Clin Rheumatol. 2019. PMID: 31278512 Review.
-
Image enhancement effect on inter and intra-observer reliability of nailfold capillary assessment.Microvasc Res. 2018 Nov;120:100-110. doi: 10.1016/j.mvr.2018.06.005. Epub 2018 Jun 27. Microvasc Res. 2018. PMID: 29958863
-
Intra-and inter-observer reliability of nailfold videocapillaroscopy - A possible outcome measure for systemic sclerosis-related microangiopathy.Microvasc Res. 2017 Jul;112:1-6. doi: 10.1016/j.mvr.2017.02.001. Epub 2017 Feb 2. Microvasc Res. 2017. PMID: 28163035
-
Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.Clin Exp Rheumatol. 2010 Sep-Oct;28(5 Suppl 62):S36-41. Epub 2010 Nov 3. Clin Exp Rheumatol. 2010. PMID: 21050543
-
[Nailfold capillaroscopy in children and adolescents with rheumatic diseases].Acta Reumatol Port. 2008 Oct-Dec;33(4):395-400. Acta Reumatol Port. 2008. PMID: 19107084 Review. Portuguese.
Cited by
-
YOLOv8-Based System for Nail Capillary Detection on a Single-Board Computer.Diagnostics (Basel). 2024 Aug 23;14(17):1843. doi: 10.3390/diagnostics14171843. Diagnostics (Basel). 2024. PMID: 39272628 Free PMC article.
-
Nailfold capillary patterns correlate with age, gender, lifestyle habits, and fingertip temperature.PLoS One. 2022 Jun 15;17(6):e0269661. doi: 10.1371/journal.pone.0269661. eCollection 2022. PLoS One. 2022. PMID: 35704663 Free PMC article.
-
Practical issues in assessing nailfold capillaroscopic images: a summary.Clin Rheumatol. 2019 Sep;38(9):2343-2354. doi: 10.1007/s10067-019-04644-9. Epub 2019 Jul 5. Clin Rheumatol. 2019. PMID: 31278512 Review.
-
CAPI-Detect: machine learning in capillaroscopy reveals new variables influencing diagnosis.Rheumatology (Oxford). 2025 Jun 1;64(6):3667-3675. doi: 10.1093/rheumatology/keaf073. Rheumatology (Oxford). 2025. PMID: 39918978 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous