Use of Evicel Fibrin Sealant in Optic Disc Pit-Associated Macular Detachment
- PMID: 28419404
- DOI: 10.3928/23258160-20170329-13
Use of Evicel Fibrin Sealant in Optic Disc Pit-Associated Macular Detachment
Abstract
Optic disc pit is a rare congenital anomaly of the optic nerve. Retinal detachment is a common complication with poor outcomes. Many surgical alternatives have been described for the treatment of this condition, producing variable results. Herein, the authors describe four cases of optic disc pit-associated macular detachment managed with pars plana vitrectomy, fluid-air exchange, drainage of subretinal fluid through the optic disc pit, temporal peripapillary laser, and application of Evicel fibrin sealant (human) (Ethicon, Bridgewater, NJ) over the optic disc head. Case 1 showed stable visual acuity and improvement of subretinal fluid. Cases 2 and 3 showed visual acuity and subretinal fluid improvements. At the 1-week follow-up visit, Case 4 showed almost total subretinal fluid absorption. The sealant invariably disappeared between 1 and 2 weeks and was tolerated by all patients. This case series suggests that Evicel fibrin sealant may be considered as an adjunctive option in the surgical treatment of optic disc pit-associated maculopathy. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:358-363.].
Copyright 2017, SLACK Incorporated.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous
