Evaluation of stability of stereotactic space defined by cone-beam CT for the Leksell Gamma Knife Icon
- PMID: 28419781
- PMCID: PMC5689865
- DOI: 10.1002/acm2.12073
Evaluation of stability of stereotactic space defined by cone-beam CT for the Leksell Gamma Knife Icon
Abstract
The Gamma Knife Icon comes with an integrated cone-beam CT (CBCT) for image-guided stereotactic treatment deliveries. The CBCT can be used for defining the Leksell stereotactic space using imaging without the need for the traditional invasive frame system, and this allows also for frameless thermoplastic mask stereotactic treatments (single or fractionated) with the Gamma Knife unit. In this study, we used an in-house built marker tool to evaluate the stability of the CBCT-based stereotactic space and its agreement with the standard frame-based stereotactic space. We imaged the tool with a CT indicator box using our CT-simulator at the beginning, middle, and end of the study period (6 weeks) for determining the frame-based stereotactic space. The tool was also scanned with the Icon's CBCT on a daily basis throughout the study period, and the CBCT images were used for determining the CBCT-based stereotactic space. The coordinates of each marker were determined in each CT and CBCT scan using the Leksell GammaPlan treatment planning software. The magnitudes of vector difference between the means of each marker in frame-based and CBCT-based stereotactic space ranged from 0.21 to 0.33 mm, indicating good agreement of CBCT-based and frame-based stereotactic space definition. Scanning 4-month later showed good prolonged stability of the CBCT-based stereotactic space definition.
Keywords: CBCT; Gamma knife; Leksell space; QA tool; icon; stereotactic radiosurgery.
© 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Figures






References
-
- Leksell L. The stereotaxic method and radiosurgery of the brain. Acta Chir Scand. 1951. Dec ;102(4):316–319. - PubMed
-
- Li W, Cho Y‐B, Ansell S, et al. The use of cone‐beam computed tomography for image‐guided Gamma knife stereotactic radiosurgery: initial clinical evaluation. Int J Radiat Oncol. 2016;96(1):214–220. - PubMed
-
- Eriksson M, Nordström H. Design and performance characteristics of a cone Beam CT system for the LGK perfexion In: 17th International Leksell Gamma Knife Society Meeting. New York: Leksell Gamma Knife Society; 2014.
-
- Elekta Instrument AB . Automatic positional delivery correction using a stereotactic CBCT in Leksell Gamma Knife® Icon™ (White Paper), 2015. Art. No. 1518415.01.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources