Beyond Wires and Seeds: Reflector-guided Breast Lesion Localization and Excision
- PMID: 28430555
- DOI: 10.1148/radiol.2017161661
Beyond Wires and Seeds: Reflector-guided Breast Lesion Localization and Excision
Abstract
Purpose To evaluate outcomes of Savi Scout (Cianna Medical, Aliso Viejo, Calif) reflector-guided localization and excision of breast lesions by analyzing reflector placement, localization, and removal, along with target excision and rates of repeat excision (referred to as re-excision). Materials and Methods A single-institution retrospective review of 100 women who underwent breast lesion localization and excision by using the Savi Scout surgical guidance system from June 2015 to May 2016 was performed. By using image guidance 0-8 days before surgery, 123 nonradioactive, infrared-activated, electromagnetic wave reflectors were percutaneously inserted adjacent to or within 111 breast targets. Twenty patients had two or three reflectors placed for bracketing or for localizing multiple lesions, and when ipsilateral, they were placed as close as 2.6 cm apart. Target and reflector were localized intraoperatively by one of two breast surgeons who used a handpiece that emitted infrared light and electromagnetic waves. Radiographs of the specimen and pathologic analysis helped verify target and reflector removal. Target to reflector distance was measured on the mammogram and radiograph of the specimen, and reflector depth was measured on the mammogram. Pathologic analysis was reviewed. Re-excision rates and complications were recorded. By using statistics software, descriptive statistics were generated with 95% confidence intervals (CIs) calculated. Results By using sonographic (40 of 123; 32.5%; 95% CI: 24.9%, 41.2%) or mammographic (83 of 123; 67.5%; 95% CI: 58.8% 75.1%) guidance, 123 (100%; 95% CI: 96.4%, 100%) reflectors were placed. Mean mammographic target to reflector distance was 0.3 cm. All 123 (100%; 95% CI: 96.4%, 100%) targets and reflectors were excised. Pathologic analysis yielded 54 of 110 malignancies (49.1%; 95% CI: 39.9%, 58.3%; average, 1.0 cm; range, 0.1-5 cm), 32 high-risk lesions (29.1%; 95% CI: 21.4%, 38.2%), and 24 benign lesions (21.8%; 95% CI: 115.1%, 30.4%). Four of 54 malignant cases (7.4%; 95% CI: 2.4%, 18.1%) demonstrated margins positive for cancer that required re-excision. Five of 110 radiographs of the specimen (4.5%; 95% CI: 1.7%, 10.4%) demonstrated increased distance between the target and reflector distance of greater than 1.0 cm (range, 1.1-2.6 cm) compared with postprocedure mammogram the day of placement, three of five were associated with hematomas, two of five migrated without identifiable cause. No related postoperative complications were identified. Conclusion Savi Scout is an accurate, reliable method to localize and excise breast lesions with acceptable margin positivity and re-excision rates. Bracketing is possible with reflectors as close as 2.6 cm. Savi Scout overcomes many limitations of other localization methods, which warrants further study. © RSNA, 2017.
Similar articles
-
Utilization of multiple SAVI SCOUT surgical guidance system reflectors in the same breast: A single-institution feasibility study.Breast J. 2018 Jul;24(4):531-534. doi: 10.1111/tbj.12979. Epub 2017 Dec 18. Breast J. 2018. PMID: 29251387
-
A Prospective, Single Arm, Multi-site, Clinical Evaluation of a Nonradioactive Surgical Guidance Technology for the Location of Nonpalpable Breast Lesions during Excision.Ann Surg Oncol. 2016 Oct;23(10):3168-74. doi: 10.1245/s10434-016-5405-y. Epub 2016 Jul 28. Ann Surg Oncol. 2016. PMID: 27469121 Clinical Trial.
-
SAVI SCOUT® localization of breast lesions as a practical alternative to wires: Outcomes and suggestions for trouble-shooting.Clin Imaging. 2018 Nov-Dec;52:280-286. doi: 10.1016/j.clinimag.2018.07.008. Epub 2018 Jul 24. Clin Imaging. 2018. PMID: 30193186
-
Savi Scout® Radar Localisation of Non-palpable Breast Lesions: Systematic Review and Pooled Analysis of 842 Cases.Anticancer Res. 2020 Jul;40(7):3633-3643. doi: 10.21873/anticanres.14352. Anticancer Res. 2020. PMID: 32620602
-
The Wire and Beyond: Recent Advances in Breast Imaging Preoperative Needle Localization.Radiographics. 2019 Nov-Dec;39(7):1886-1906. doi: 10.1148/rg.2019190041. Epub 2019 Sep 27. Radiographics. 2019. PMID: 31560614 Review.
Cited by
-
Innovations in image-guided preoperative breast lesion localization.Br J Radiol. 2018 May;91(1085):20170740. doi: 10.1259/bjr.20170740. Epub 2018 Feb 6. Br J Radiol. 2018. PMID: 29271240 Free PMC article. Review.
-
Evaluation of a Surgical Navigation System for Localization and Excision of Nonpalpable Lesions in Breast and Axillary Surgery.Breast J. 2023 Dec 23;2023:9993852. doi: 10.1155/2023/9993852. eCollection 2023. Breast J. 2023. PMID: 38162957 Free PMC article.
-
Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT® System.Cancers (Basel). 2021 May 17;13(10):2409. doi: 10.3390/cancers13102409. Cancers (Basel). 2021. PMID: 34067552 Free PMC article.
-
Evaluation of the nonradioactive inducible magnetic seed system Magseed for preoperative localization of nonpalpable breast lesions - initial clinical experience.Contemp Oncol (Pozn). 2020;24(1):51-54. doi: 10.5114/wo.2020.93677. Epub 2020 Mar 13. Contemp Oncol (Pozn). 2020. PMID: 32514238 Free PMC article.
-
Preoperative non-palpable breast lesion localization, innovative techniques and clinical outcomes in surgical practice: A systematic review and meta-analysis.Breast. 2021 Aug;58:93-105. doi: 10.1016/j.breast.2021.04.007. Epub 2021 Apr 22. Breast. 2021. PMID: 33991806 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials