. 2017 Nov;27(11):4563-4570.
doi: 10.1007/s00330-017-4816-x. Epub 2017 Apr 21.

3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times

Affiliations

3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times

Osamah M Abdulaal et al. Eur Radiol. 2017 Nov.

Abstract

Objectives: To investigate optimised isotropic 3D turbo spin echo (TSE) and gradient echo (GRE)-based pulse sequences for visualisation of articular cartilage lesions within the knee joint.

Methods: Optimisation of experimental imaging sequences was completed using healthy volunteers (n=16) with a 3-Tesla (3T) MRI scanner. Imaging of patients with knee cartilage abnormalities (n=57) was then performed. Acquired sequences included 3D proton density-weighted (PDW) TSE (SPACE) with and without fat-suppression (FS), and T2*W GRE (TrueFISP) sequences, with acquisition times of 6:51, 6:32 and 5:35 min, respectively.

Results: One hundred sixty-one confirmed cartilage lesions were detected and categorised (Grade II n=90, Grade III n=71). The highest sensitivity and specificity for detecting cartilage lesions were obtained with TrueFISP with values of 84.7% and 92%, respectively. Cartilage SNR mean for PDW SPACE-FS was the highest at 72.2. TrueFISP attained the highest CNR means for joint fluid/cartilage (101.5) and joint fluid/ligament (156.5), and the lowest CNR for cartilage/meniscus (48.5). Significant differences were identified across the three sequences for all anatomical structures with respect to SNR and CNR findings (p-value <0.05).

Conclusion: Isotropic TrueFISP at 3T, optimised for acquisition time, accurately detects cartilage defects, although it demonstrated the lowest contrast between cartilage and meniscus.

Key points: • Cartilage is better visualised with 3D TrueFISP than 3D SPACE sequences. • 3D TrueFISP is a reliable sequence for detecting low- and high-grade cartilage defects. • 3D TrueFISP at 3T provides excellent contrast between cartilage and joint fluid.

Keywords: Articular; Cartilage; Evidence-based practice; Knee joint; Magnetic resonance imaging.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiographics. 2011 Jan-Feb;31(1):37-61 - PubMed
    1. Skeletal Radiol. 2012 Feb;41(2):169-78 - PubMed
    1. AJR Am J Roentgenol. 2012 Feb;198(2):W173-80 - PubMed
    1. Osteoarthritis Cartilage. 2013 Mar;21(3):428-33 - PubMed
    1. Semin Roentgenol. 2010 Oct;45(4):238-49 - PubMed

LinkOut - more resources