Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr;9(1):11-16.
doi: 10.1055/s-0037-1601325. Epub 2017 Mar 24.

Functional Outcome of Fixation of Complex Intra-articular Distal Radius Fractures with a Variable-Angle Distal Radius Volar Rim Plate

Affiliations

Functional Outcome of Fixation of Complex Intra-articular Distal Radius Fractures with a Variable-Angle Distal Radius Volar Rim Plate

M Spiteri et al. J Hand Microsurg. 2017 Apr.

Abstract

Aim To evaluate the outcome of these complex fractures using a volar approach and the DePuy Synthes variable-angle 2.4-mm distal radius rim plate. This plate is precontoured to the volar rim for placement distal to the watershed line allowing purchase of the rim fragment of the lunate facet. Its low profile and smooth edges are designed to minimize flexor tendon irritation. Method We report on a consecutive series of far distal AO-23B3 and AO-23C3 fractures treated using this plate in a tertiary hand center between November 2011 and May 2014. Range of motion, grip strength, and complications were assessed at the final clinical review. Disabilities of the arm, shoulder, and hand (DASH) and patient evaluation measure (PEM) scores were assessed at 12 months after surgery. Results Twenty-six patients were included in this review. Six patients were lost to follow-up at 3 months. This plate was used in isolation in 17 cases, and in combination with a dorsal plate, in cases of dorsal instability after volar plating, in 10 patients. DASH and PEM scores 1 year after surgery were 17.6 and 27%, respectively. Visual analog scores for patient treatment satisfaction and severity of pain showed good satisfaction with treatment and mild intermittent pain on activity. Postoperative range of motion was variable and grip strength was of 71% of the uninjured contralateral side. There were no cases of flexor or extensor tendon rupture. Tendon irritation was noted in two patients. Removal of metal was performed in four patients. Loss of reduction occurred in one case and neurologic complications in two cases. Conclusion This implant is specifically designed for the management of far distal complex intra-articular fractures of the distal radius. Despite the complexity of these fracture patterns and the challenge they pose to accurate reduction and stable fixation, outcomes were satisfactory in this small series. There were no cases of tendon rupture. Removal of metal is not necessary in all cases, but prompt removal should be performed in cases of tendon irritation in view of the risk of tendon rupture.

Keywords: distal radius fracture; open reduction and internal fixation; patient evaluation measure; variable-angle distal radius rim plate.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Sagittal and axial computed tomographic scans showing involvement of lunate fossa and far distal articular comminution.
Fig. 2
Fig. 2
Axial computed tomographic scan showing varying degrees of involvement of distal radioulnar joint.
Fig. 3
Fig. 3
Range of motion after open reduction and internal fixation.
Fig. 4
Fig. 4
PA and lateral radiographs of distal radius fracture showing distal position of rim plate.

Similar articles

Cited by

References

    1. Jupiter J B, Marent-Huber M. Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicentre prospective case series. J Bone Joint Surg Am. 2010;92(1):96–106. - PubMed
    1. Chen N C, Jupiter J B, Jupiter J. Management of distal radial fractures. J Bone Joint Surg Am. 2007;89(9):2051–2062. - PubMed
    1. O'Shaughnessy M A, Shin A Y, Kakar S. Volar marginal rim fracture fixation with volar fragment-specific hook plate fixation. J Hand Surg Am. 2015;40(8):1563–1570. - PubMed
    1. Forward D P, Sithole J S, Davis T R. The internal consistency and validity of the patient evaluation measure for outcomes assessment in distal radius fractures. J Hand Surg Eur Vol. 2007;32(3):262–267. - PubMed
    1. Melone C P Jr. Articular fractures of the distal radius. Orthop Clin North Am. 1984;15(2):217–236. - PubMed