Radiation exposure during intramedullary nailing
- PMID: 28449852
- DOI: 10.1016/j.injury.2017.04.023
Radiation exposure during intramedullary nailing
Abstract
Surgeons should aim to keep radiation exposure "As Low As Reasonably Achievable (ALARA)" during intramedullary nailing and other minimally invasive surgical procedures. This requires understanding the principles of ionizing radiation and methods for minimizing exposure risk. The main source of radiation exposure to surgical personnel during fluoroscopy is from scattered radiation. Since radiation scatter is mainly directed towards the fluoroscopy source, the best configuration during surgery to reduce radiation dose to the surgeon is to position the fluoroscopic source below the operating room table and the image collector above the table. During cross table imaging, the surgeon should stand on the side with the image collector to minimize their exposure to radiation scatter. To reduce scattered radiation the patient must be placed as close to the image collector and as far away from the x-ray tube as possible. Standing farther away from the patient can exponentially reduce radiation exposure. The hands usually have the greatest dose exposure to radiation during surgical procedures, but they are far less radiosensitive than the eyes or thyroid. To minimize exposure to the hands, a surgeon should use the hands-off technique taking fluoroscopic images only when his or her hands are farthest from the radiographic field. Lead gowns, lead thyroid shields, and lead glasses, further reduces an individual's exposure to radiation.
Keywords: Fluoroscopy; Radiation exposure protection; Radiation safety.
Copyright © 2017 Elsevier Ltd. All rights reserved.
Similar articles
-
Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.Injury. 1998 Jul;29(6):461-8. doi: 10.1016/s0020-1383(98)00088-6. Injury. 1998. PMID: 9813705
-
Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy.Spine (Phila Pa 1976). 2013 Nov 15;38(24):2108-12. doi: 10.1097/BRS.0b013e3182a8270d. Spine (Phila Pa 1976). 2013. PMID: 23963017
-
Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.Spine (Phila Pa 1976). 2012 Jun 15;37(14):1240-4. doi: 10.1097/BRS.0b013e31824589d5. Spine (Phila Pa 1976). 2012. PMID: 22198350
-
ALARA in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients--a white paper executive summary.J Am Coll Radiol. 2006 Sep;3(9):686-8. doi: 10.1016/j.jacr.2006.04.008. J Am Coll Radiol. 2006. PMID: 17412149
-
Occupational radiation exposure to nursing staff during cardiovascular fluoroscopic procedures: A review of the literature.J Appl Clin Med Phys. 2018 Nov;19(6):282-297. doi: 10.1002/acm2.12461. Epub 2018 Oct 8. J Appl Clin Med Phys. 2018. PMID: 30294978 Free PMC article. Review.
Cited by
-
A study on legal and medical dimensions of radiation exposure in neurosurgery clinics in Turkish practice.Surg Neurol Int. 2020 Nov 18;11:397. doi: 10.25259/SNI_703_2020. eCollection 2020. Surg Neurol Int. 2020. PMID: 33274112 Free PMC article.
-
The hidden risk of ionizing radiation in the operating room: a survey among 258 orthopaedic surgeons in Brazil.Patient Saf Surg. 2020 Apr 22;14:16. doi: 10.1186/s13037-020-00238-6. eCollection 2020. Patient Saf Surg. 2020. PMID: 32336990 Free PMC article.
-
Fast and accurate distal locking of interlocked intramedullary nails using computer-vision and a 3D printed device.3D Print Med. 2024 Aug 7;10(1):28. doi: 10.1186/s41205-024-00221-2. 3D Print Med. 2024. PMID: 39110149 Free PMC article.
-
Kuntscher Nail: A Forgotten Entity Yet a Reliable Modality in Treatment of Winquist Type I and II Closed Femoral Shaft Fractures.Cureus. 2020 Sep 23;12(9):e10608. doi: 10.7759/cureus.10608. Cureus. 2020. PMID: 33123425 Free PMC article.
-
The use of ionising radiation in orthopaedic surgery: principles, regulations and managing risk to surgeons and patients.Eur J Orthop Surg Traumatol. 2021 Jul;31(5):947-955. doi: 10.1007/s00590-021-02955-9. Epub 2021 Apr 7. Eur J Orthop Surg Traumatol. 2021. PMID: 33825954 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials