Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial
- PMID: 28455159
- DOI: 10.1016/j.gie.2017.04.013
Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial
Abstract
Background and aims: Biliary anastomotic stricture occurs in 15% to 20% of patients after deceased orthotopic liver transplantation (OLT). It is usually treated endoscopically with multiple plastic stents (MPSs), although the use of fully covered self-expandable metal stents (cSEMSs) is emerging. This study aims to compare the efficacy and safety of cSEMSs versus MPSs in these patients.
Methods: A single-center, open-label, randomized clinical trial was performed. Patients were randomized to single cSEMSs for 6 months or to MPS placement, exchanged every 3 months over 1 year. The primary outcome was stricture resolution. Crossover therapy was considered for failure or recurrence. Secondary outcomes were sustained improvement, morbidity, and mortality.
Results: Between October 2009 and January 2014, 162 patients with post-OLT biliary adverse events were assessed for eligibility. Sixty-four were prospectively randomized (1:1) to cSEMSs or MPSs. Baseline characteristics were comparable. Technical success was 100%. Median follow-up was 36.4 and 32.9 months for the cSEMS and MPS groups, stricture resolution at last stent removal was achieved in 83.3% and 96.5% (P = .19), and stricture recurrence was observed in 32% and 0%, respectively (P < .01). Adverse events occurred in 23.3% and 6.4% of ERCPs in the cSEMS and MPS groups, respectively (P < .01), with 13.3% of acute pancreatitis in the cSEMS group and 2.1% in the MPS group (P < .01).
Conclusions: cSEMSs were comparable with MPSs regarding post-OLT biliary anastomotic stricture resolution. cSEMSs allowed fewer procedures and had a positive effect on cost. Duration of treatment with cSEMSs should be further investigated. Sphincterotomy should be considered for all patients. (Clinical trial registration number: NCT 01148199.).
Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Comment in
-
Better too big than too small?Gastrointest Endosc. 2019 Mar;89(3):650-651. doi: 10.1016/j.gie.2018.09.040. Gastrointest Endosc. 2019. PMID: 30784508 No abstract available.
-
Response.Gastrointest Endosc. 2019 Mar;89(3):651-652. doi: 10.1016/j.gie.2018.10.039. Gastrointest Endosc. 2019. PMID: 30784509 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources