. 2017 May;99(5):390-393.
doi: 10.1308/rcsann.2017.0022.

Mechanical complications of central venous catheterisation in trauma patients

Affiliations

Mechanical complications of central venous catheterisation in trauma patients

J Odendaal et al. Ann R Coll Surg Engl. 2017 May.

Abstract

INTRODUCTION Central venous catheterisation (CVC) is a commonly performed procedure in a wide variety of hospital settings and is associated with appreciable morbidity. There is a paucity of literature focusing on mechanical complications specifically in the trauma setting. The aim of our study was to determine the spectrum of mechanical complications in a high-volume trauma centre in a developing world setting where ultrasound guidance was not available. METHODS A retrospective study was performed analysing data from a four-year period at the Pietermaritzburg Metropolitan Trauma Service in South Africa. RESULTS A total of 178 mechanical complications (18%) occurred in 1,015 patients undergoing CVC: 117 pneumothoraces, 25 malpositions, 18 catheter dislodgements, 14 arterial cannulations, one air embolism, one chylothorax, one pleural cannulation and one retained guide-wire. The internal jugular vein (IJV) approach was associated with a higher overall complication rate than the subclavian vein (SCV) approach (24% vs. 13%, p<0.001). Pneumothorax (73% vs. 57%, p<0.001) and arterial cannulation (15% vs. 0%, p<0.001) were more common with the IJV. Catheter dislodgement (21% vs. 0%, p<0.001) was more common with the SCV. Junior doctors performed 66% of the CVCs and this was associated with a significantly higher complication rate (20% vs. 12%, p<0.001). CONCLUSIONS CVC carries appreciable morbidity, with pneumothorax being the most frequent mechanical complication. The SCV was the most commonly used approach at our institution. The majority of CVCs were performed by junior doctors and this was associated with a considerable complication rate.

Keywords: Central venous line; Mechanical complications; Trauma.

PubMed Disclaimer

Figures

Figure 1
Figure 1
A central venous catheter inserted via the right subclavian vein with catheter tip in the left subclavian vein

References

    1. Ives C, Moe D, Inaba K et al. . Ten years of mechanical complications of central venous catheterization in trauma patients. Am Surg 2012; : 545–549. - PubMed
    1. McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med 2003; : 1,123–1,133. - PubMed
    1. Bannon MP, Heller SF, Rivera M. Anatomic considerations for central venous cannulation. Risk Manag Healthc Policy 2011; : 27–39. - PMC - PubMed
    1. Ruesch S, Walder B, Tramér MR. Complications of central venous catheters: internal jugular versus subclavian access – a systematic review. Crit Care Med 2002; : 454–460. - PubMed
    1. Sznajder JI, Zveibil FR, Bitterman H et al. . Central vein catheterization. Failure and complication rates by three percutaneous approaches. Arch Intern Med 1986; : 259–261. - PubMed