Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2017 May-Jun;65(3):66-70.

Effect of high- or low-concentration bleaching agents containing calcium and/or fluoride on enamel microhardness

  • PMID: 28475089
Comparative Study

Effect of high- or low-concentration bleaching agents containing calcium and/or fluoride on enamel microhardness

Isabella Spinardi Furlan et al. Gen Dent. 2017 May-Jun.

Abstract

The aim of this in vitro study was to evaluate enamel microhardness following bleaching treatments using either high- or low-concentration hydrogen peroxide (HP) agents containing calcium and/or fluoride. Sixty enamel blocks were bleached with 1 of 6 different bleaching agents (n = 10). The high-concentration HP agents were Whiteness HP Maxx (35% HP), Whiteness HP Blue (35% HP, 2% calcium gluconate), Pola Office+ (37.5% HP, 5% potassium nitrate), and Opalescence Boost (38% HP, 1.1% fluoride ion, 3% potassium nitrate). The low-concentration HP agents evaluated were Pola Day (9.5% HP) and White Class (10% HP, potassium nitrate, calcium, fluoride). High-concentration agents were applied in 3 sessions, whereas low-concentration agents were applied for 14 days. Knoop microhardness measurements were taken on the surface of the enamel before bleaching, at various timepoints during bleaching, and 14 days after the final bleaching treatment. The 2-way analysis of variance test showed that microhardness values were significantly influenced by the bleaching agent (P < 0.001) and application time (P < 0.001). The Tukey test showed that enamel bleached with Whiteness HP Maxx or White Class presented lower microhardness values than did the enamel treated with the remaining products. There was a reduction in micro-hardness values up to the end of the treatment. The results showed that the composition, concentration, and application protocol for each bleaching agent influenced the enamel microhardness values in that the microhardness decreased over time, regardless of the agent used or the addition of calcium and/or fluoride.

Keywords: dental bleaching; hydrogen peroxide; microhardness.

PubMed Disclaimer

Conflict of interest statement

Disclaimer: The authors have no financial, economic, commercial, or professional interests related to topics presented in the manuscript.

Similar articles

Cited by

Publication types

LinkOut - more resources