The association between AHA CPR quality guideline compliance and clinical outcomes from out-of-hospital cardiac arrest
- PMID: 28476474
- DOI: 10.1016/j.resuscitation.2017.05.003
The association between AHA CPR quality guideline compliance and clinical outcomes from out-of-hospital cardiac arrest
Abstract
Background: Measures of chest compression fraction (CCF), compression rate, compression depth and pre-shock pause have all been independently associated with improved outcomes from out-of-hospital (OHCA) cardiac arrest. However, it is unknown whether compliance with American Heart Association (AHA) guidelines incorporating all the aforementioned metrics, is associated with improved survival from OHCA.
Methods: We performed a secondary analysis of prospectively collected data from the Resuscitation Outcomes Consortium Epistry-Cardiac Arrest database. As per the 2015 American Heart Association (AHA) guidelines, guideline compliant cardiopulmonary resuscitation (CPR) was defined as CCF >0.8, chest compression rate 100-120/minute, chest compression depth 50-60mm, and pre-shock pause <10s. Multivariable logistic regression models controlling for Utstein variables were used to assess the relationship between global guideline compliance and survival to hospital discharge and neurologically intact survival with MRS ≤3. Due to potential confounding between CPR quality metrics and cases that achieved early ROSC, we performed an a priori subgroup analysis restricted to patients who obtained ROSC after ≥10min of EMS resuscitation.
Results: After allowing for study exclusions, 19,568 defibrillator records were collected over a 4-year period ending in June 2015. For all reported models, the reference standard included all cases who did not meet all CPR quality benchmarks. For the primary model (CCF, rate, depth), there was no significant difference in survival for resuscitations that met all CPR quality benchmarks (guideline compliant) compared to the reference standard (OR 1.26; 95% CI: 0.80, 1.97). When the dataset was restricted to patients obtaining ROSC after ≥10min of EMS resuscitation (n=4,158), survival was significantly higher for those resuscitations that were guideline compliant (OR 2.17; 95% CI: 1.11, 4.27) compared to the reference standard. Similar findings were obtained for neurologically intact survival with MRS ≤3 (OR 3.03; 95% CI: 1.12, 8.20).
Conclusions: In this observational study, compliance with AHA guidelines for CPR quality was not associated with improved outcomes from OHCA. Conversely, when restricting the cohort to those with late ROSC, compliance with guidelines was associated with improved clinical outcomes. Strategies to improve overall guideline compliance may have a significant impact on outcomes from OHCA.
Keywords: Cardiopulmonary resuscitation; Heart arrest; Resuscitation; Survival.
Copyright © 2017 Elsevier B.V. All rights reserved.
Similar articles
-
A quantitative analysis of out-of-hospital pediatric and adolescent resuscitation quality--A report from the ROC epistry-cardiac arrest.Resuscitation. 2015 Aug;93:150-7. doi: 10.1016/j.resuscitation.2015.04.010. Epub 2015 Apr 25. Resuscitation. 2015. PMID: 25917262 Free PMC article.
-
CPR quality during out-of-hospital cardiac arrest transport.Resuscitation. 2017 May;114:34-39. doi: 10.1016/j.resuscitation.2017.02.016. Epub 2017 Feb 24. Resuscitation. 2017. PMID: 28242210
-
Quality of bystander cardiopulmonary resuscitation during real-life out-of-hospital cardiac arrest.Resuscitation. 2017 Nov;120:63-70. doi: 10.1016/j.resuscitation.2017.09.006. Epub 2017 Sep 10. Resuscitation. 2017. PMID: 28903056
-
Community first responders for out-of-hospital cardiac arrest in adults and children.Cochrane Database Syst Rev. 2019 Jul 19;7(7):CD012764. doi: 10.1002/14651858.CD012764.pub2. Cochrane Database Syst Rev. 2019. PMID: 31323120 Free PMC article.
-
Impact of dispatcher-assisted cardiopulmonary resuscitation on neurologically intact survival in out-of-hospital cardiac arrest: a systematic review.Scand J Trauma Resusc Emerg Med. 2021 May 24;29(1):70. doi: 10.1186/s13049-021-00875-5. Scand J Trauma Resusc Emerg Med. 2021. PMID: 34030706 Free PMC article.
Cited by
-
Impacts of chest compression cycle length and real-time feedback with a CPRmeter® on chest compression quality in out-of-hospital cardiac arrest: study protocol for a multicenter randomized controlled factorial plan trial.Trials. 2020 Jul 8;21(1):627. doi: 10.1186/s13063-020-04536-3. Trials. 2020. PMID: 32641090 Free PMC article.
-
The Compliance of Current Small Animal CPR Practice With RECOVER Guidelines: An Internet-Based Survey.Front Vet Sci. 2019 Jun 11;6:181. doi: 10.3389/fvets.2019.00181. eCollection 2019. Front Vet Sci. 2019. PMID: 31245396 Free PMC article.
-
Quality of Cardiopulmonary Resuscitation and 5-Year Survival Following in-Hospital Cardiac Arrest.Open Access Emerg Med. 2021 Dec 16;13:553-560. doi: 10.2147/OAEM.S341479. eCollection 2021. Open Access Emerg Med. 2021. PMID: 34938129 Free PMC article.
-
Efficacy of a Simplified Feedback Trainer for High-Quality Chest Compression Training: A Randomized Controlled Simulation Study.Front Public Health. 2021 Oct 14;9:675487. doi: 10.3389/fpubh.2021.675487. eCollection 2021. Front Public Health. 2021. PMID: 34722430 Free PMC article.
-
Perfusion parameters and target values during extracorporeal cardiopulmonary resuscitation: a scoping review protocol.BMJ Open. 2019 Aug 30;9(8):e030562. doi: 10.1136/bmjopen-2019-030562. BMJ Open. 2019. PMID: 31473622 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous