Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr 13:8:25.
doi: 10.4103/ijpvm.IJPVM_299_16. eCollection 2017.

Maximal Oxygen Consumption, Respiratory Volume and Some Related Factors in Fire-fighting Personnel

Affiliations

Maximal Oxygen Consumption, Respiratory Volume and Some Related Factors in Fire-fighting Personnel

Touraj Khazraee et al. Int J Prev Med. .

Abstract

Background: Firefighters for difficult activities and rescue of damaged people must be in appropriate physical ability. Maximal oxygen capacity is an indicator for diagnosis of physical ability of workers. This study aimed to assess the cardiorespiratory system and its related factors in firefighters.

Methods: This study was conducted on 110 firefighters from various stations. An self-administered questionnaire (respiratory disorders questionnaire, Tuxworth-Shahnavaz step test, and pulmonary function test) was used to collection of required data. Average of humidity and temperature was 52% and 17°C, respectively. Background average noise levels were between 55 and 65 dB. Data were analyzed using SPSS software (version 19).

Results: The mean age of the study participants was 32 ± 6.2 years. The means of forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and FEV1/FVC were 92% ±9.4%, 87% ±9.2%, and 80% ±6.1%, respectively. The participants' mean VO2-max was 2.79 ± 0.29 L/min or 37.34 ± 4.27 ml/kg body weight per minute. The results revealed that weight has a direct association with vital capacity (VC), FVC, and peak expiratory flow. In addition, height was directly associated with VC, FVC, and VO2-max (P < 0.05). However, there was an inverse and significant association between height and FEV1/FVC (r = -0.23, P < 0.05). Height, weight, body mass index, and waist circumference were directly associated with VO2-max.

Conclusions: The findings of this study showed that the amount of maximum oxygen consumption is close with the proposed range of this parameter among firefighters in other studies. Furthermore, the results of the study revealed that individuals had normal amounts of lung volume index. This issue can be attributed to the appropriate usage of respiratory masks.

Keywords: Firefighter; maximal oxygen consumption; respiratory volume.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

Figures

Figure 1
Figure 1
Diagram of Tuxworth-Shahnavaz Protocol

Similar articles

Cited by

References

    1. Bishop P, Ray P, Reneau P. A review of the ergonomics of work in the US military chemical protective clothing. Int J Ind Ergon. 1995;15:271–83.
    1. Baker SJ, Grice J, Roby L, Matthews C. Cardiorespiratory and thermoregulatory response of working in fire-fighter protective clothing in a temperate environment. Ergonomics. 2000;43:1350–8. - PubMed
    1. Holloszy JO, Schultz J, Kusnierkiewicz J, Hagberg JM, Ehsani AA. Effects of exercise on glucose tolerance and insulin resistance. Brief review and some preliminary results. Acta Med Scand Suppl. 1986;711:55–65. - PubMed
    1. Manning JE, Griggs TR. Heart rates in fire fighters using light and heavy breathing equipment: Similar near-maximal exertion in response to multiple work load conditions. J Occup Environ Med. 1983;25:215–8. - PubMed
    1. Wilson JR, Sharples S. Evaluation of Human Work. Florida: CRC Press; 2015.