Sensitive and non-invasive assessment of hepatocellular iron using a novel room-temperature susceptometer
- PMID: 28483679
- DOI: 10.1016/j.jhep.2017.04.019
Sensitive and non-invasive assessment of hepatocellular iron using a novel room-temperature susceptometer
Abstract
Background & aims: Liver iron accumulates in various chronic liver diseases where it is an independent factor for survival and carcinogenesis. We tested a novel room-temperature susceptometer (RTS) to non-invasively assess liver iron concentration (LIC).
Methods: Two hundred and sixty-four patients with or without signs of iron overload or liver disease were prospectively enrolled. Thirty-five patients underwent liver biopsy with semiquantitative iron determination (Prussian Blue staining), atomic absorption spectroscopy (AAS, n=33), or magnetic resonance imaging (MRI, n=15).
Results: In vitro studies demonstrated a highly linear (r2=0.998) association between RTS-signal and iron concentration, with a detection limit of 0.3mM. Using an optimized algorithm, accounting for the skin-to-liver capsule distance, valid measurements could be obtained in 84% of cases. LIC-RTS showed a significant correlation with LIC-AAS (r=0.74, p<0.001), LIC-MRI (r=0.64, p<0.001) and hepatocellular iron (r=0.58, p<0.01), but not with macrophage iron (r=0.32, p=0.30). Normal LIC-RTS was 1.4mg/g dry weight. Besides hereditary and transfusional iron overload, LIC-RTS was also significantly elevated in patients with alcoholic liver disease. The areas under the receiver operating characteristic curve (AUROC) for grade 1, 2 and 3 hepatocellular iron overload were 0.72, 0.89 and 0.97, respectively, with cut-off values of 2.0, 4.0 and 5.0mg/g dry weight. Notably, the positive and negative predictive values, sensitivity, specificity and accuracy of severe hepatic iron overload (HIO) (grade ≥2) detection, were equal to AAS and superior to all serum iron markers. Depletion of hepatic iron could be efficiently monitored upon phlebotomy.
Conclusions: RTS allows for the rapid and non-invasive measurement of LIC. In comparison to MRI, it could be a cost-effective bedside method for LIC screening. Lay summary: Novel room-temperature susceptometer (RTS) allows for the rapid, sensitive, and non-invasive measurement of liver iron concentration. In comparison to MRI, it could be a cost-effective bedside method for liver iron concentration screening.
Keywords: Alcoholic liver disease; Anemia; Atomic absorption spectroscopy; Cirrhosis; Hemochromatosis; Iron overload; Liver fibrosis; Liver iron; Liver stiffness; Magnetic susceptibility; Susceptometry.
Copyright © 2017 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Comment in
-
Is room temperature susceptometer really an accurate method to assess hepatocellular iron?J Hepatol. 2017 Dec;67(6):1345-1346. doi: 10.1016/j.jhep.2017.07.021. Epub 2017 Aug 5. J Hepatol. 2017. PMID: 28789881 No abstract available.
-
Reply to: "Is room temperature susceptometry really an accurate method to assess hepatocellular iron?".J Hepatol. 2017 Dec;67(6):1346-1348. doi: 10.1016/j.jhep.2017.07.020. Epub 2017 Aug 7. J Hepatol. 2017. PMID: 28797582 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical