Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
- PMID: 28484294
- PMCID: PMC5402364
- DOI: 10.5455/aim.2017.25.28-33
Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
Abstract
Objective: This study objective was to evaluate interobserver agreement between individual pairs of three nuclear medicine physicians in interpretation of renal cortical scintigraphy in children with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right).
Materials and methods: Thirty children were imaged in planar and SPECT mode per protocol upon the injection of Tc-99m DMSA dose adjusted to their body weight. Patients were classified according to diagnoses into four groups. Three nuclear medicine physicians interpreted the findings blindly and independently. Renal defects were interpreted as focal and diffuse, per three renal segments. For the raters we calculated simple percentage agreement, the Cohen kappa statistic with 95% confidence intervals, and the overall kappa defining the levels of reliability as almost perfect or perfect, substantial, moderate, fair and slight agreement.
Results: Interobserver agreement in planar interpretation was 77,2% (kappa=0.59; 95% confidence interval, 0.41 to 0.75) and SPECT 72,9% (kappa= 0,57; 95% confidence interval, 0,41 to 0,72). In planar interpretation, all individual pairs had moderate agreements except one that had a substantial agreement. In SPECT, all the pairs had moderate agreements except one that had an almost perfect agreement. Overall agreement per kidney site was on planar 73,4% for the left (kappa=0,54, moderate agreement), and 81,1% for the right kidney (kappa 0,63, substantial agreement). On SPECT, there was 72,2% agreement for the left (kappa=0,59, mode rate agreement), and 73,7% for the right kidney (kappa=0,54, moderate agreement). Overall agreement per diagnoses ranged from 70-88,9% on planar (kappa= -0,04 to 0,79), and 50-100% on SPECT (kappa=-0,02-1,000) indicating agreements from slight to substantial.
Discussion: Our results suggest acceptable levels of interobserver agreement in all individual pairs of raters with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). For the mode of acquisition, we would recommend hybrid imaging SPECT/CT method to be used whenever possible in the detection of renal cortical defects on Tc-99m-DMSA scintigraphy.
Keywords: Interobserver variability; SPECT; Tc-99m-DMSA; cortical scintigraphy; planar.
Conflict of interest statement
• Conflict of interest: none declared
Figures


Similar articles
-
Interrater Reliability of 99mTc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children.Diagnostics (Basel). 2020 Dec 17;10(12):1101. doi: 10.3390/diagnostics10121101. Diagnostics (Basel). 2020. PMID: 33348530 Free PMC article.
-
Reliability of DMSA for the diagnosis of renal parenchymal abnormality in children.Eur J Nucl Med. 2000 Nov;27(11):1610-6. doi: 10.1007/s002590000349. Eur J Nucl Med. 2000. PMID: 11105816
-
Comparison of 99mTc-DMSA dual-head SPECT versus high-resolution parallel-hole planar imaging for the detection of renal cortical defects.AJR Am J Roentgenol. 2009 Aug;193(2):333-7. doi: 10.2214/AJR.08.1788. AJR Am J Roentgenol. 2009. PMID: 19620428
-
Comparison of Tc-99m DMSA Renal Planar Scan and SPECT for Detection of Cortical Defects in Infants with Suspected Acute Pyelonephritis.Indian J Pediatr. 2019 Sep;86(9):797-802. doi: 10.1007/s12098-019-02969-6. Epub 2019 May 16. Indian J Pediatr. 2019. PMID: 31098932
-
Current Status of Radionuclide Renal Cortical Imaging in Pyelonephritis.J Nucl Med Technol. 2019 Dec;47(4):309-312. doi: 10.2967/jnmt.119.227942. Epub 2019 Jun 10. J Nucl Med Technol. 2019. PMID: 31182659 Review.
Cited by
-
Interrater Reliability of 99mTc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children.Diagnostics (Basel). 2020 Dec 17;10(12):1101. doi: 10.3390/diagnostics10121101. Diagnostics (Basel). 2020. PMID: 33348530 Free PMC article.
References
-
- Piepsz A, Ham HR. Pediatric applications of renal nuclear medicine. Semin Nucl Med. 2006 Jan;36(1):16–35. - PubMed
-
- Piepsz A, Blaufox MD, Gordon I, Granerus G, Majd M, O’Reilly P, Rosenberg AR, Rossleigh MA, Sixt R. Concensus on Renal Cortical Scintigraphy in Children With Urinary Tract Infection. Scientific Committee of Radionuclides in Nephrourology. Semin Nucl Med. 1999 Apr;29(2):160–74. - PubMed
-
- Piepsz A. Cortical scintigraphy and urinary tract infection in children. Nephrol Dial Transplant. 2002;17:560–2. - PubMed
-
- Rossleigh MA. Renal cortical scintigraphy and diuresis renography in infants and children. J Nucl Med. 2001;42:91–5. - PubMed
-
- De Sadeleer C, Bossuyt A, Goes E, Piepsz A. Renal Tehnetium-99m-DMSA SPECT in Normal Volunteers. J Nucl Med. 1996 Aug;37(8):1346–9. - PubMed
LinkOut - more resources