Comparative Study
. 2017 Dec;20(12):1101-1106.
doi: 10.1016/j.jsams.2017.04.017. Epub 2017 Apr 21.

Comparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents

Affiliations
Comparative Study

Comparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents

Joseph J Scott et al. J Sci Med Sport. 2017 Dec.

Abstract

Objective: To determine the comparability and feasibility of wrist- and hip-worn accelerometers among free-living adolescents.

Design: 89 adolescents (age=13-14years old) from eight secondary schools in New South Wales (NSW), Australia wore wrist-worn GENEActiv and hip-worn ActiGraph (GT3X+) accelerometers simultaneously for seven days and completed an accelerometry behavior questionnaire.

Methods: Bivariate correlations between the wrist- and hip-worn out-put were used to determine concurrent validity. Paired samples t-test were used to compare minutes per day in moderate-to-vigorous physical activity (MVPA). Group means and paired sample t-tests were used to analyze participants' perceptions of the wrist- and hip-worn monitoring protocols to assist with determining the feasibility.

Results: Wrist-worn accelerometry compared favorably with the hip-worn in average activity (r=0.88, p<0.001) and MVPA (r=0.84 p<0.001, mean difference=3.54min/day, SD=12.37). The wrist-worn accelerometer had 50% fewer non-valid days (75 days, 12%) than the hip-worn accelerometer (n=152, 24.4%). Participants reported they liked to wear the device on the wrist (p<0.01), and that it was less uncomfortable (p=0.02) and less embarrassing to wear on the wrist (p<0.01). Furthermore, that they would be more willing to wear the device again on the wrist over the hip (p<0.01).

Conclusions: Our findings reveal there is a strong linear relationship between wrist- and hip-worn accelerometer out-put among adolescents in free-living conditions. Adolescent compliance was significantly higher with wrist placement, with participants reporting that it was more comfortable and less embarrassing to wear on the wrist.

Keywords: ActiGraph; Compliance; GENEActiv; Perceptions; Physical activity; Youth.