Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Oct;285(1):250-260.
doi: 10.1148/radiol.2017162148. Epub 2017 May 16.

Improvement in Ventilation-Perfusion Mismatch after Bronchoscopic Lung Volume Reduction: Quantitative Image Analysis

Affiliations

Improvement in Ventilation-Perfusion Mismatch after Bronchoscopic Lung Volume Reduction: Quantitative Image Analysis

Sei Won Lee et al. Radiology. 2017 Oct.

Abstract

Purpose To evaluate whether bronchoscopic lung volume reduction (BLVR) increases ventilation and therefore improves ventilation-perfusion (V/Q) mismatch. Materials and Methods All patients provided written informed consent to be included in this study, which was approved by the Institutional Review Board (2013-0368) of Asan Medical Center. The physiologic changes that occurred after BLVR were measured by using xenon-enhanced ventilation and iodine-enhanced perfusion dual-energy computed tomography (CT). Patients with severe emphysema plus hyperinflation who did not respond to usual treatments were eligible. Pulmonary function tests, the 6-minute walking distance (6MWD) test, quality of life assessment, and dual-energy CT were performed at baseline and 3 months after BLVR. The effect of BLVR was assessed with repeated-measures analysis of variance. Results Twenty-one patients were enrolled in this study (median age, 68 years; mean forced expiratory volume in 1 second [FEV1], 0.75 L ± 0.29). After BLVR, FEV1 (P < .001) and 6MWD (P = .002) improved significantly. Despite the reduction in lung volume (-0.39 L ± 0.44), both ventilation per voxel (P < .001) and total ventilation (P = .01) improved after BLVR. However, neither perfusion per voxel (P = .16) nor total perfusion changed significantly (P = .49). Patients with lung volume reduction of 50% or greater had significantly better improvement in FEV1 (P = .02) and ventilation per voxel (P = .03) than patients with lung volume reduction of less than 50%. V/Q mismatch also improved after BLVR (P = .005), mainly owing to the improvement in ventilation. Conclusion The dual-energy CT analyses showed that BLVR improved ventilation and V/Q mismatch. This increased lung efficiency may be the primary mechanism of improvement after BLVR, despite the reduction in lung volume. © RSNA, 2017 Online supplemental material is available for this article.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources