Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2017 Sep;88(9):876-886.
doi: 10.1902/jop.2017.160698. Epub 2017 May 18.

Soft Tissue Changes Around Immediately Placed Implants: A Systematic Review and Meta-Analyses With at Least 12 Months of Follow-Up After Functional Loading

Affiliations
Meta-Analysis

Soft Tissue Changes Around Immediately Placed Implants: A Systematic Review and Meta-Analyses With at Least 12 Months of Follow-Up After Functional Loading

Bassam M Kinaia et al. J Periodontol. 2017 Sep.

Abstract

Background: Immediate implant placement (IIP) is predictable but can lead to esthetic challenges, including midfacial recession (MFR) and papillary height (PH) loss. The aim of this systematic review is to examine the effect of IIP on MFR and PH after at least 12 months of functional loading.

Methods: Literature review of the Cochrane and MEDLINE electronic databases and hand search up to January 2016 identified eligible studies. Four reviewers independently assessed data quality and methodology.

Results: A total of 106 articles satisfied the inclusion criteria. Twelve studies qualified for three meta-analyses. MFR was slightly less in conventional implant placement (CIP) than in IIP, but the result was not statistically significant (mean difference [MD] -0.064 mm; P = 0.687). Similarly, there was better PH maintenance in CIPs, with statistical significance for distal PH (DPH) only (cumulative PH: MD -0.396, P = 0.010; DPH: MD -0.765, P <0.001; mesial PH [MPH]: MD -0.285, P = 0.256). MFR was slightly less in IIP with thick versus thin biotypes, but not statistically significantly different (MD -0.373, P = 0.243). Pooled data showed statistically significantly less MFR and better PH maintenance in IIP with thick biotype (MFR: MD -0.478, P <0.001; cumulative PH: MD -0.287, P <0.001; MPH: MD -0.288, P <0.001; DPH: MD -0.310, P <0.001). Non-significantly less MFR (MD 0.253, P = 0.384) and significantly better PH maintenance were found in IIP with immediate provisionalization versus conventional restoration (MD -0.519, P = 0.028).

Conclusions: IIP in thick biotype and with immediate provisionalization had less MFR and better PH than IIP in thin biotype or with delayed restoration. However, these findings should be interpreted with caution due to high heterogeneity, which was calculated using comprehensive meta-analysis statistical software that took into account sample size and different treatment groups, and limited qualified studies.

Keywords: Dental implants; esthetics; gingival recession; meta-analysis; review.

PubMed Disclaimer

Substances

LinkOut - more resources